Domestic Hot Water Control; Reheat Mode; Scheduled Mode; Scheduled + Reheat Mode - Daikin Altherma 3 R F EBVZ16S18D 6V Series Operation Manual

Table of Contents

Advertisement

2 Adjust the desired leaving water temperature.
a
b
2
35
°C
Main zone
a
b
3
45
°C
Additional zone
a Actual leaving water temperature
b Desired leaving water temperature
5.7

Domestic hot water control

5.7.1

Reheat mode

In reheat mode, the DHW  tank continuously heats up to the
temperature shown on the home screen (example: 50°C) when the
temperature drops below a certain value.
T t
1
60°C
50°C
40°C
15°C
00:00
07:00
T
DHW tank temperature
t
t
Time
INFORMATION
When the DHW tank mode is reheat, the risk for capacity
shortage and comfort problem is significant. In case of
frequent reheat operation, space heating/cooling function
is regularly interrupted.
INFORMATION
In situations when very low or no DHW consumption is
anticipated, Reheat only mode can result in colder than
expected DHW temperatures. In such situations, it is
recommended to switch to one of the following modes:
▪ Schedule only
▪ Schedule + reheat
5.7.2

Scheduled mode

In
scheduled
mode,
the
DHW  tank
corresponding to a schedule. The best time to allow the tank to
produce hot water is at night, because the space heating demand is
lower.
Example:
EBVZ16S18+23D
Daikin Altherma 3 R F
4P643606-1B – 2022.08
+
+
3
2
4
t
14:00
21:00
produces
hot
water
T t
1
2
60°C
50°C
40°C
15°C
00:00
07:00
T
DHW tank temperature
t
t
Time
▪ Initially, the DHW  tank temperature is the same as the
temperature of the domestic water entering the DHW  tank
(example: 15°C).
▪ At 00:00 the DHW tank is programmed to heat up the water to a
preset value (example: Comfort = 60°C).
▪ During the morning, you consume hot water and the DHW  tank
temperature decreases.
▪ At 14:00 the DHW tank is programmed to heat up the water to a
preset value (example: Eco = 50°C). Hot water is available again.
▪ During the afternoon and evening, you consume hot water again
and the DHW tank temperature decreases again.
▪ At 00:00 the next day, the cycle repeats.
5.7.3

Scheduled + reheat mode

In scheduled + reheat mode, the domestic hot water control is the
same as in scheduled mode. However, when the DHW  tank
temperature drops below a preset value (=reheat tank temperature –
hysteresis value; example: 35°C), the DHW  tank heats up until it
reaches the reheat set point (example: 45°C). This ensures that a
minimum amount of hot water is available at all times.
Example:
T t
1
2
60°C
50°C
45°C
35°C
15°C
00:00
07:00
T
Domestic hot water tank temperature
t
t
Time
5.7.4

Using DHW powerful operation

About powerful operation
Powerful operation allows the domestic hot water to be heated by
the backup heater. Use this mode on days when there is more hot
water usage than usual.
To check if powerful operation is active
If
is displayed on the home screen, powerful operation is active.
Activate or deactivate Powerful operation as follows:
1 Go to [5.1]: Tank > Powerful operation
2 Turn powerful operation Off or On.
Usage example: You immediately need more hot water
You are in the following situation:
▪ You already consumed most of your domestic hot water.
5 Operation
4
3
5
t
14:00
21:00
3
4
5
t
14:00
21:00
Operation manual
13

Advertisement

Table of Contents
loading

Table of Contents