4. Troubleshooting Guide
Trouble Condition
Visual Indications
Low battery
Fault Mode
end of Unit Life
end of Unit Life Hush
Mode (after push/
release test/Hush
button during end
of Life)
network error
seconds
network error Hush
(after button push
during network error)
If you require further information please contact Product Support at 1-800-880-6788 or write us at:
Kidde Canada Inc., P.O. Box 40, Apsley, ON K0L 1A0. Our internet address is www.kiddecanada.com.
Audible Indications
Chirp every 60 sec, voice every 30
sec: "Replace alarm."
Voice stops after 5 mins.
Chirp every 30 sec.
Voice every 30 sec: "Error, see trouble
shooting guide"
After 5 mins: no voice message
Double chirp every 30 sec.
Amber
First 5 mins: Voice every 30 sec:
"Replace alarm, press button to
temporarily silence." Voice stops after
LED
5 mins. After 7 days: Chirps continue.
Voice every 30 sec for 5 mins:
"Replace alarm."
blinks
Voice "Temporarily Silenced."
End of Unit Life chirps silenced for
every
24 hrs. (7 days after End of Unit Life
chirps begin, the chirps cannot be
silenced.)
5
Chime every 30 secs. Voice every 30
sec: "Connection lost. Press button
to temporarily silence."
After 5 min: no voice messages
(Note: network must have 3 or more
alarms for voice messages.)
Voice "Temporarily
Silenced."
Action:
* Remove, discharge, dispose unit, and replace as soon
as possible.
* See Cleaning Your Alarm section.
* Push Test/Hush button once to attempt to reset
the unit .
* Red LED will blink out an error code (number of blinks)
when Test/Hush button is push/released once. Report
the number of blinks to customer service if needed.
* Push/release Test/Hush button to temporarily silence
(see End of Unit Life Hush Mode section below)
* Remove, discharge, dispose unit, and replace as soon
as possible.
* Remove, discharge, dispose unit, and replace as soon
as possible.
* Push/release the Test/Hush button once to silence for
24 hrs at a time.
* Red LED will blink out an error code (number of blinks)
when Test/Hush button is push/released once. Report
the number of blinks to customer service if needed.
* Push and hold Test/Hush button until two beeps
are heard (approx 4 sec) and then release the button
to try to rejoin. Or reset (section 9.3) and then rejoin
(section 9.2).
* If error persists, remove, discharge, and replace alarm
as soon as possible.
7