7. Selecting Microstep Resolution and Drive Output Current

Microstep resolutions and output current are programmable, the former can be set from full-step to
102,400 steps/rev and the latter can be set from 0.5A to 7.0A. See more information about Microstep
and Output Current Setting in Section 13.
However, when it's not in software configured mode, this Drive uses an 8-bit DIP switch to set
microstep resolution, and motor operating current, as shown below:

Microstep Resolution Selection

When it's not in software configured mode, microstep resolution is set by SW5, 6, 7, 8 of the DIP
switch as shown in the following table:
Microstep
Steps/rev.(for 1.8°motor)
1 to 512
Default/Software configured
2
400
4
800
8
1600
16
3200
32
6400
64
12800
128
25600
5
1000
10
2000
20
4000
25
5000
40
8000
50
10000
Tel: +086 0755-26434369
DM870 Digital Stepping Driver Manual V1.0
SW5
SW6
SW7
ON
ON
ON
OFF
ON
ON
ON
OFF
ON
OFF
OFF
ON
ON
ON
OFF
OFF
ON
OFF
ON
OFF
OFF
OFF
OFF
OFF
ON
ON
ON
OFF
ON
ON
ON
OFF
ON
OFF
OFF
ON
ON
ON
OFF
OFF
ON
OFF
9
Web Site: www.leadshine.com
100
125

Current Settings

For a given motor, higher Drive current will make the motor to output more torque, but at the same
time causes more heating in the motor and Drive. Therefore, output current is generally set to be such
that the motor will not overheat for long time operation. Since parallel and serial connections of
motor coils will significantly change resulting inductance and resistance, it is therefore important to
set Drive output current depending on motor phase current, motor leads and connection methods.
Phase current rating supplied by motor manufacturer is important in selecting Drive current, however
the selection also depends on leads and connections.
When it's not in software configured mode, the first three bits (SW1, 2, 3) of the DIP switch are used
to set the dynamic current. Select a setting closest to your motor's required current.

Dynamic current setting

SW8
Peak Current
ON
Default/Software configured (0.5 to 7.0A)
ON
2.6A
ON
3.4A
ON
4.0A
ON
4.8A
ON
5.4A
ON
6.1A
ON
7.0A
OFF
Notes:
Due to motor inductance, the actual current in the coil may be smaller than the dynamic
OFF
current setting, particularly under high speed condition.
OFF

Standstill current setting

OFF
SW4 is used for this purpose. OFF meaning that the standstill current is set to be half of the selected
OFF
dynamic current, and ON meaning that standstill current is set to be the same as the selected dynamic
OFF
current.
Tel: +086 0755-26434369
DM870 Digital Stepping Driver Manual V1.0
20000
ON
OFF
25000
OFF
OFF
RMS Current
SW1
OFF
1.8A
ON
2.4A
OFF
2.8A
ON
3.4A
OFF
ON
3.8A
OFF
4.3A
ON
5.0A
10
OFF
OFF
OFF
OFF
SW2
SW3
OFF
OFF
OFF
OFF
ON
OFF
ON
OFF
OFF
ON
OFF
ON
ON
ON
ON
ON
Web Site: www.leadshine.com

Advertisement

Table of Contents
loading

Table of Contents