TS-1000 Loop Back Test Result
Result
Result counter
Table 4-14 Descriptions of the TS-1000 Loop Back Test Web Page Screen Objects
Please use the PLANET FT-90Xv2 or GT-80X and GT-90X as the Remote device.
Notice:

4.7.4 802.3ah Setup

When enable 802.3ah OAM function, all 802.3ah OAMPDU packets will trap to embedded CPU.
Software will implement auto discovery procedure. With hardware support, software controls the 802.3ah remote loop back
procedure. Hardware can also detect dying gasp even and interrupt CPU to send dying gasp even notification OAMPDU.
All other functions defined by 802.3ah are implemented using embedded CPU.
When remote device is in loop back mode, hardware can support change looped test frame's DA, SA or both as user
defined. Hardware can also set to don't change looped test frame.
This function provides 802.3ah Setup of Managed Media Converter. Press the "Apply" button to save the current
configuration of Managed Media Converter. The screen in
Setup object of Managed Media Converter.
Display the TS-1000 Loop Back Test Result. Fail or Pass.
Display the value of Counter Result.
Figure 4-39 802.3ah Setup Web Page screen
Figure 4-39
appears and
Table 4-15
-45-