Planet FT-1105A User Manual

10/100base-tx to 100base-fx redundant media converter

Advertisement

Quick Links

10/100Base-TX to 100Base-FX
Redundant Media Converter
FT-1105A / FT-1205A
User's Manual

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the FT-1105A and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Planet FT-1105A

  • Page 1 10/100Base-TX to 100Base-FX Redundant Media Converter FT-1105A / FT-1205A User’s Manual...
  • Page 2 Trademarks Copyright © PLANET Technology Corp. 2007. Contents subject to which revision without prior notice. PLANET is a registered trademark of PLANET Technology Corp. All other trademarks belong to their respective owners. Disclaimer PLANET Technology does not warrant that the hardware will...
  • Page 3: Fcc Warning

    FCC Warning This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
  • Page 4 Revision PLANET Fast Ethernet Redundant Media Converter User’s Manual FOR MODELS: FT-1105A / FT-1205A Revision: 1.1 (November, 2007) Part No.: 2010-AA3520-002...
  • Page 5: Table Of Contents

    Chapter 1 OVERVIEW ... 6 Chapter 2 PRODUCT FEATURES ... 8 Chapter 3 CHECKLIST ... 10 Chapter 4 PRODUCT OUTLOOK ... 11 Chapter 5 DIP SWITCH ... 12 Chapter 6 INSTALLING THE CONVERTER ... 14 6.1 Stand-alone Installation ... 14 6.2 Chassis Installation and Rack Mounting ...
  • Page 6: Chapter 1 Overview

    10/100Base-TX and 100Base-FX. About the Redundant Media Converter The FT-1105A and FT-1205A are 3-Port Redundant Media Converters which support conversion between 10/100Base- TX and 100Base-FX network. Different with the other one-port channel media converter, the Redundant Media Converters are...
  • Page 7 The SFP slot supports single-mode, multi-mode and WDM small-form factory type transceiver modules for your needs. With 100Base-FX SFP ports, the FT-1105A and FT-1205A are with high reliability and flexibility to extend the distance up to 2Km, 20Km, or longer. It depends on the 100Base-FX SFP transceiver modules.
  • Page 8: Chapter 2 Product Features

    • Complies with IEEE 802.3, IEEE 802.3u 10/100Base-TX, 100Base-FX • IEEE 802.3x Full-Duplex Flow-Control, Back-Pressure in Half- Duplex eliminate packets loss Interface • FT-1105A: Dual 10/100Base-TX Copper, One 100Base-FX SFP Fiber optic ● FT-1205A: Dual 10/100Base-TX Copper ● Auto-Negotiation for 10/100Base-TX Half-Duplex or Full- Duplex ●...
  • Page 9 ● DIP Switch for 3-Port operation with Fast Ethernet switch mode or Redundant mode ● DIP switch for LPR (Loop back Reply) on / off selection ● Compact size, easy installation ● Co-work with PLANET 700/1000R/1500) family Media Chassis (MC-...
  • Page 10: Chapter 3 Checklist

    Chapter 3 CHECKLIST Your FT-1105A / FT-1205A carton should contain the following items:  The Redundant Fast Ethernet Converter  AC-DC Power Adapter (Output: 5VDC, 2A max.)  This user’s manual If any item is missing or damaged, please consult the dealer from whom you purchased your Redundant Fast Ethernet Converter.
  • Page 11: Chapter 4 Product Outlook

    ● Port-1 100Base SFP slot (Primary Port) ● Port-2 100Base SFP slot (Backup Port) ● Port-3 TP connector FT-1105A / FT-1205A Rear Panel One DC jack for DC power input and DIP switch to set 3-Port switch mode / 2-Port Redundant and Loop back reply Enable/...
  • Page 12: Chapter 5 Dip Switch

    FT-1105A Switch 1 Switch 2 2-Port Redundant (FT-1105A) When TP Redundancy is enabled, TP Port-2 and TP Port-3 are configured as either forwarding or disabled. At any given time, one port will be disabled and one port will be forwarding.
  • Page 13 3-Port Switch When Fiber Redundancy is disabled, all ports (Port-1, Port-2 and Port-3) act as normal bridging ports. FT-1105A / FT-1205A supports OAM/TS-1000 protocol for remote status monitor. To enable the OAM support function, set the DIP Switch 2 “On”.
  • Page 14: Chapter 6 Installing The Converter

    SFP port without having to power down the converter. To install a FT-1105A / FT-1205A stand-alone, on a desktop or shelf, simply complete the following steps: Step 1: Turn off the power of the device/station in a network to which the FT-1105A / FT-1205A will be attached.
  • Page 15: Chassis Installation And Rack Mounting

    Step 4: Connect the fiber cable. Attach the duplex LC connector on the network cable into the SFP transceiver. Step 5: Attach fiber cable from the FT-1105A/FT-1205A to the fiber network. TX, RX must be paired at both ends. Step 6: Connect the 5VDC power adapter to the FT-1105A/FT- 1205A and verify that the Power LED lights up.
  • Page 16 Step 2: Carefully slide in the module until it is fully and firmly fitted into the slot of the chassis. Figure 2-1: Insert a media converter into an available slot Step 3: Attach a rack-mount bracket to each side of the Chassis with supplied screws attached to the package.
  • Page 17: Chapter 7 Redundancy

    Chapter 7 Redundancy FT-1105A FT-1205A redundancy highly redundant-mode supports destination port of a packet is link down, it forwards the packet to the other port of the backup pair. The following figure shows the redundant function. Main Main Traffic is changed from Primary -Port to Backup-Port ●...
  • Page 18: Chapter 8 Loop Back Reply

    Chapter 8 Loop Back Reply The FT-1105A / FT-1205A supports auto loop back reply while receive loop back test packets on fiber port. Enable this function to tell the converter to reply fiber signals request from Web Smart media converter, such as PLANET FT-90x. You can use this to check whether the converter can communicate with partner converter.
  • Page 19: Chapter 9 Led Indicators

    Chapter 9 LED INDICATORS The LED indicators give you instant feedback on status of the converter: System Color Function Green Lit: Power on. FT-1105A / FT-1205A -10/100Base-TX Port Color Lit: LNK/ Green Blink: Off: Lit: Orange Off: FT-1105A - 100Base-FX SFP Port Function Indicate that the port is link up.
  • Page 20 Color Lit: LNK/ Green Blink: Off: Lit: FDX/ Green Off: FT-1205A -100Base-FX SFP Port Color Lit: Green Blink: Off: Function Indicate that the port is link up. Indicate that the converter is actively sending or receiving data over that port. Indicate that the port is link down.
  • Page 21: Chapter 10 Product Specification

    DIP Switches DIP 2: On Loop Back Reply Enable IEEE 802.3, 10Base-T Standards IEEE 802.3u, 100Base-TX, 100Base-FX IEEE 802.3x Flow Control FT-1105A 1 x 10/100Base-TX port 2 x 100Base-FX port Port 1 (Primary) Port 2 (Backup) System: One Power LED, TP Port : ●...
  • Page 22: Appendix A

    APPENDIX A A.1 Device's RJ-45 Pin Assignments 10/100Mbps, 10/100Base-TX Contact 4, 5, 7, 8 Implicit implementation of the crossover function within a twisted-pair cable, or at a wiring panel, while not expressly forbidden, is beyond the scope of this standard. A.2 RJ-45 cable pin assignment 1 (TX +) 2 (TX -)
  • Page 23: Fiber Optical Cable Connection Parameter

    There are 8 wires on a standard UTP/STP cable and each wire is color-coded. The following shows the pin allocation and color of straight cable and crossover cable connection: Figure A-1: Straight-Through and Crossover Cable Please make sure your connected cables are with same pin assignment and color as above picture before deploying the cables into your network.
  • Page 24: Power Information

    A.4 Power Information The power jack of FT-1105A / FT-1205A is with 2.5mm in the central post and required +5VDC power input. It will conform to the bundled AC-DC adapter and Planet’s Media Chassis. Should you have the problem to make the power connection, please contact your local sales representative.

This manual is also suitable for:

Ft-1205a

Table of Contents