Basic system connection

This system allows 2 types of connection methods, "Station-to-station wiring" and "Home-run wiring". Select the method suitable for
the application and usage of the system. Both connection methods can be combined.
Station-to-station (daisy-chained) wiring
Door station 1
JP-DA
JP-DV
JP-DVF
JP-DVF-L
A1
A2
or
GT-D
1
2
2
Door station 2
NP
2
Door station 3
NP
2
Door station 4
NP
*
Same as door station 1.
Door release
Electric door
strike
EL-12S
Electric door
strike
EL-12S
PT
AC transformer
An EL-12S (AC 12 V 0.125 A, DC 12
V 0.2 A) or equivalent electric door
strike and a separate AC transformer
are required.
*
Run separate cables for audio/
video and door release.
*
Door release contact: AC/DC 24 V,
0.5 A (Minimum Contact : 100 mV
DC, 0.1 mA)
(N/O dry closure contact L1, L2).
*
To enable door release for door 3
and 4, see page 11.
8
Master station
(ID = 1)
Sub master station 1 (ID = 2)
JP-4MED
JP-4HD
M (OUT)
M (IN)
M (OUT)
1A1
2
1A2
NP
2A1
2A2
3A1
3A2
4A1
4A2
4-pin option connector
b4
b3
P. 12
b2
b1
S
A1
2
S
A2
NP
2
L1
L1
NP
2
L2
L2
NP
S3E
S3
S2E
S2
S1E
S1
P. 12
SW
SW
V
V+
2
PS24
P
Sub master station 2 (ID = 3)
JP-4HD
Sub master station 3 (ID = 4)
JP-4HD
Sub master station 4 (ID = 5)
JP-4HD
M (IN)
M (IN)
M (OUT)
M (OUT)
M (IN)
M (OUT)
2
PS24
P
Optional call
extension speaker
IER-2
: Power supply
PS24
PS-2420D
L
N
230 V AC 50/60 Hz
:
CAT5e (non-shielded)
2
:
Ø1.0mm, 18AWG 2 conductor cable
NP: Non-polarized
P: Polarized
Sub master station 5 (ID = 6)
JP-4HD
Sub master station 6 (ID = 7)
JP-4HD
Sub master station 7
(ID = 8)
JP-4HD
M (IN)
M (OUT)
M (IN)
M (OUT)
2
P
PS-2420
PS-2420S
PS-2420UL
AC
100V - 240V
50/60 Hz
+
-
24 V DC2A
M (IN)
M (OUT)
PS24
+
-
24V
DC2A