Wiring Distance - Aiphone JPW-BA Installation Manual

Table of Contents

Advertisement

Wiring distance

The wiring distance between the power supply and each unit differs depending on the power supply method. (
*
[H]
[A]
[B]
[G]
[B]
:
Master station
Wiring distance between each device
[A]
Door station - master station
[B]
Door station - long distance adaptor
[C]
Long distance adaptor - master station
[D]
Master station - power supply
[E]
Long distance adaptor - power supply
[F]
Master station - external display
[G]
Long distance adaptor - CCTV camera
[H]
Master station - multiple door release adaptor
[I]
Master station - optional call extension speaker
[J]
Total wiring distance of residential stations
[I]
[F]
Station-to-station (daisy-chained) wiring
Refer to "Selecting power supply method". (→P. 6)
[D]
[C]
PS24
[E]
or
[D]
[C]
PS24
[E]
:
Sub master station
Coaxial
3 m (10')
15 m (50')
[J]
Home-run wiring
PS24
[J] = Ja + Jb + Jc + --- + Jh
Refer to "Selecting power supply method". (→P. 6)
:
CAT5e (non-shielded)
CAT5e
Ø0.65 mm
(24AWG)
(22 AWG)
-
-
50 m (165')
-
-
100 m (330')
-
-
50 m (165')
-
-
5 m (16')
-
-
50 m (165')
-
-
-
-
50 m (165')
-
-
75 m (245')
-
300 m (980')
→ P. 6)
or
Jb
PS24
Jc
Ja
PS24
Jh
:
Power supply
PS24
Wire diameter
Ø0.8 mm
Ø1.0 mm
(20 AWG)
(18 AWG)
100 m (330')
100 m (330')
150 m (490')
200 m (650')
75 m (245')
100 m (330')
5 m (16')
10 m (33')
75 m (245')
100 m (330')
-
-
75 m (245')
100 m (330')
100 m (330')
150 m (490')
-
Ø1.2 mm
(16 AWG)
100 m (330')
200 m (650')
100 m (330')
10 m (33')
100 m (330')
100 m (330')
150 m (490')
5