InfiRay Tube Series Operating Manual
Hide thumbs Also See for Tube Series:

Advertisement

Tube Series
Operating Manual
V1.0
InfiRay Technologies Co., Ltd.

Advertisement

Table of Contents
loading

Summary of Contents for InfiRay Tube Series

  • Page 1 Tube Series Operating Manual V1.0 InfiRay Technologies Co., Ltd.
  • Page 2: Specifications

    Specifications Model TD50L Resolution, pixels 1440×1080 Frame Rate, Hz Objective Lens, mm 50 (F1.2) Field of View, º 6.6×4.9 Magnification, × 4.0~16.0 Smooth zoom Support Eye Relief, mm Diopter Adjustment, D -4~+4 Type LCOS Resolution, pixels 1280×960 Video record resolution, pixels 1440×1080 Capture resolution, pixels 1440×1080...
  • Page 3: Package Contents

    It is equipped with a starlight-level low illuminance chip, which can restore true colors and details in both day and night. The Tube series has a variety of battery-powered solutions with long operating hours, and can be widely used for hunting, observation and positioning in low visibility conditions.
  • Page 4: Device Composition

     Convenient operation interface; IV. Device Composition 1. Eye cup 2. Eyepiece focusing ring 3. Camera button 4. Display brightness button 5. Power button 6. Image mode button 7. Rotary encoder 8. USB cap 9. Type-C interface 10. LED indicator 11.
  • Page 5 device Return to the Advanced menu upper menu —— —— screen without saving changes Image Turn on/off the PIP Switch the image Mode Home screen function —— mode Button Turn on/off the Display Adjust the stadiametric Brightness Home screen display ——...
  • Page 6: Battery Charging

    VI. Battery Charging The Tube series adopts a dual power supply system (built-in chargeable Lithium-ion battery pack and a replaceable 18500 battery). The normal working time of the dual power supply system can be up to 13 hours. The battery should be fully charged before first use.
  • Page 7: Safety Measures

    Switching between two types of batteries The Tube series supports the dual power supply system: built-in Lithium-ion battery pack and replaceable 18500 battery, while supporting a USB power supply.  If both batteries are installed in the Tube device, two battery icons are displayed on the...
  • Page 8: External Power Supply

     When the device is in use, the replaceable battery can also be replaced. At this time, it will switch to the internal battery automatically. VII. External Power Supply The Tube series supports external power supplies, such as the portable power source for a mobile phone (5V). ...
  • Page 9: Startup And Configuration

    To ensure firing accuracy, please fix the Tube at a proper position on the weapon. The Tube series needs to be fixed with an adapter clamp, such as a simple Picatinny rail  clamp provided in the package. The Tube series adopts a tubular body design with a diameter of 30mm, which is compatible with standard clamps with a diameter of 30mm, such as those of day scope.
  • Page 10 (5) to wake it up. IX. Zeroing The Tube series adopts the "freezing" zeroing method. It is recommended to carry out the zeroing operation within the range of operating temperature of the scope.  Fix the scope on the weapon with a frock clamp;...
  • Page 11  Press and hold the rotary encoder (7) to enter the advanced menu screen, select the zeroing option, and press the rotary encoder (7) to enter the submenu of the zeroing function;  According to the selected target distance, select or add the new zeroing distance (refer to "Zeroing-Zeroing Distance-Set Zeroing Distance"...
  • Page 12: Digital Zoom

    XII. Photo Taking and Video Recording The Tube series is equipped with a built-in 16 GB memory space, which allows photo taking and video recording of an observed target. Image and video files will be named after time, so it is recommended to complete the system date and time settings in the advanced menu before using the photo taking and video recording function (refer to "Advanced Menu-Settings-Date/Time").
  • Page 13 camera button (3) to start the video recording;  A recording icon and a prompt box showing the recording time will appear in the upper right corner of the display, with the time format as 00:00:00 (hours: minutes: seconds);  During recording, you can also take a photo by pressing the camera button (3);...
  • Page 14 : Wi-Fi is disabled; : Wi-Fi is enabled) Clock (You can set up date and time in the settings menu, or download the InfiRay Outdoor APP to synchronize phone time to the device) 7. The power status of the replaceable battery (18500 battery) 8.
  • Page 15: Shortcut Menu

    XIV. Shortcut Menu The shortcut menu can be used for a quick setup of the basic settings of some common functions, including reticle style, reticle color, image sharpness, and zeroing distance. Press and hold the encoder (7) to save the operation and return to the home screen. On the home screen, press the rotary encoder (7) to go to the shortcut menu screen;...
  • Page 16: Advanced Menu

    XV. Advanced Menu:  On the home screen, press and hold the rotary encoder (7) for 3s to go to the main menu; Turn the rotary encoder (7) to switch between the function options in the main menu,  rotate clockwise to move down and anticlockwise to move up; The function options in the main menu are cyclical: when the cursor reaches the last ...
  • Page 17 Composition and Description of Main Menu Enabling/Disabling Wi-Fi  Press and hold the rotary encoder (7) to open the advanced menu; Wi-Fi  Turn the rotary encoder (7) to select the "Wi-Fi" function option;  Press the rotary encoder (7) to enable/disable Wi-Fi; ...
  • Page 19 Please set up the zeroing profile and zeroing distance before carrying out any zeroing operation. The Tube series supports any zeroing distance between 1 and 999 meters.  Press and hold the rotary encoder (7) to open the advanced menu;...
  • Page 20  Press the rotary encoder (7) to go to the zeroing screen;  The X axis and Y axis coordinates of the reticle are displayed on the top left corner of the display;  Aim the reticle center of the scope at the bull's eye at the target distance and shoot, and then observe the position of the actual point of impact;...
  • Page 21 symbols are displayed above and below the number;  Turn the encoder (7) to set the number value of the current position, which can be switched between 0 to 9;  Press the rotary encoder (7) to switch between the positions of hundreds, tens and ones digits;...
  • Page 22 When the device is in the shooting status, the standby mode is disabled. This function is used to set the language, units of measure, status auto hiding, factory reset, and device information query. Setting the system date Settings  Press the rotary encoder (7) to open the secondary menu of "Settings".
  • Page 23 Setting the system time  Press the rotary encoder (7) to open the secondary menu of "Settings".  Press the rotary encoder (7) to select "Time". The 24-hour system is used with the hour and minute displayed.  Press the rotary encoder (7) to activate the time reset function;...
  • Page 24 of "Settings".  Select "Language", and press the rotary encoder (7) to open the secondary menu for language selection;  Turn the rotary encoder (7) to switch between English and Russian;  Press the rotary encoder (7) to confirm and save the selection, and return to the menu screen;...
  • Page 25 Hiding  Press the rotary encoder (7) to open the secondary menu of "Settings".  Select "Status Auto Hiding", and press the rotary encoder (7) to open the secondary menu for status auto hiding;  Turn the rotary encoder (7) to select On or Off; ...
  • Page 26 Digital Zoom: ×4.0 Standby: Off Wi-Fi: Off Language: English Unit of Measure: Meter Status Auto Hiding: Off Querying device information  Press the rotary encoder (7) to open the secondary menu of "General".  Turn the rotary encoder (7) to select "Info"; Info ...
  • Page 27 PIP window is also enlarged to 2×. *Due to some factors, this function is not available for some regions. 17. Stadiametric Rangefinding The Tube series provides stadiametric rangefinding, which allows you to calculate the approximate distance from a target with a known size. ...
  • Page 28 You can operate the buttons and the menu only after the GUI information is displayed.  XIX. Wi-Fi The Tube series has a built-in Wi-Fi module. The device can connect wirelessly to a mobile apparatus (laptop or smartphone) via Wi-Fi. In the advanced menu, enable Wi-Fi. For detailed operations, refer to "Advanced ...
  • Page 29 Setting Wi-Fi name and password The Tube series allows you to change the name and password of the device Wi-Fi in the app. After the scope is connected to the mobile device, locate the "Settings" icon in the  InfiRay Outdoor image screen and tap it to open the "Settings" screen;...
  • Page 30: Technical Inspection

    InfiRay Outdoor saves the last connected device automatically. Therefore, once you open InfiRay Outdoor, it automatically detects an update in the background even when the scope is not connected to a phone or laptop. If an update is available and the mobile device accesses the internet, you can download the update first.
  • Page 31: Troubleshooting

    XXIII. Troubleshooting The following table lists all problems that are likely to occur during device operation. Check and address problems by referring to this table. If faults not included in this table occur or you cannot fix the fault, return the device to the vendor or supplier for troubleshooting. Fault Possible Causes Solutions...
  • Page 32 the zeroing point may move slightly. Set the scope according to the contents as specified in "Startup and Image Setup". Check the outer surface of the objective lens and eyepiece, and if The scope can not Set error necessary, wipe off any dust and frost focus on it.

This manual is also suitable for:

Td50l

Table of Contents