    InfiRay Outdoor • Geni Series• Operating Manual www.infirayoutdoor.com IMPORTANT SAFETY INFORMATION - If the device has been damaged or the battery is defective, send the device to our after-sales service for repair. Environmental influences User information on the disposal of electrical and electronic devices...
  • Page 3 Observation with and without glasses observation, remote hunting observations and for civil use. This device is not Thanks to the flexible eyeshade, the Geni series can be used with or without a toy for children. glasses. It offers a full field of view in both cases.
  • Page 4: Technical Specifications

    InfiRay Outdoor • Geni Series• Operating Manual www.infirayoutdoor.com Technical Specifications GH35 GL50 GH50 Model GL35 Microbolometer Type Uncooled 640×512 384×288 640×512 Resolution, pixels 384×288 Pixel Size, um NETD, mk ≤35 Frame Rate, Hz Optical Characteristics F50mm /1.1 Objective Lens F35mm /1.0 12.6×9.4...
  • Page 5: Operational Characteristics

    InfiRay Outdoor • Geni Series• Operating Manual www.infirayoutdoor.com Battery Type / Capacity 4400mAh Internal battery + 3300mAh Replaceable battery ★ Max. Operating Time (at t=22℃), h External Power Supply 5V (Type C USB) Operational Characteristics Max. Recoil Power on Rifled Weapon, m/s²...
  • Page 6: Package Contents

    InfiRay Outdoor • Geni Series• Operating Manual www.infirayoutdoor.com Package Contents light and are not affected by strong lights. Geni series can be widely used in the night hunting, observation and terrain navigation, search and rescue Thermal Imaging Riflescopes operations etc.
  • Page 7: Components And Controls

    InfiRay Outdoor • Geni Series• Operating Manual www.infirayoutdoor.com Components and Controls 1. Eyeshade 2. Eyepiece adjustment ring 3. Type C port 4. Down button / Photography button 5. Menu / M button 6. Up button / Zoom button 7. Power button 8.
  • Page 8: Description Of Controls

    InfiRay Outdoor • Geni Series• Operating Manual www.infirayoutdoor.com Description of Controls Button Current Status Short Press Long Press Device is off —— Power on the device Device is on Standby the device Power off Power Button Standby mode Wake up the device ——...
  • Page 9: Battery Pack Installation

    ⚫ Geni can only be powered by this battery pack. If other battery packs Geni series are supplied with a rechargeable Li-ion Battery Pack IBP-2 are used, it may cause irreparable loss, damage to the device, and can which allows operation for up to 5 hours. Please Remember to charge the even possibly cause fire.
  • Page 10 InfiRay Outdoor • Geni Series• Operating Manual www.infirayoutdoor.com a rated output voltage not exceeding 5V. ⚫ After the battery is fully charged, remove the battery pack from the ⚫ Plug the adapter into a 100-240V power socket (20) for charging.
  • Page 11: Safety Precautions

    ⚫ Don’t leave the Battery Pack with a charger connected to the mains Geni series support external power supply, such as the mobile power bank longer than over 24 hours after full charge.
  • Page 12: Operation

    9 “Zeroing”. Installation of Rifle Mount ➢ Before using the Geni series, you need to install the Rifle Mount (21) on the bottom of your riflescope. ➢ The mounting holes (24) in the base of the riflescope enable the Mount (21) to be installed in one of the multiple positions.
  • Page 13 Power On and Image Settings ➢ Open the lens cover (9). Geni series feature to use the “Freeze” zeroing method. Zeroing should be ➢ Press and hold down the Power (7) button to turn on the scope. done at the operation temperatures by following the order of these steps: ➢...
  • Page 14 InfiRay Outdoor • Geni Series• Operating Manual www.infirayoutdoor.com Zeroing - submenu Zeroing Distance - Reset Zeroing Distance). current selected option, and the icon turns into blue. ➢ Press the Up (6) button to move the reticle right or up and the Down (4) ➢...
  • Page 15: Digital Zoom

    There are three calibration modes: Automatic (A), Manual (M) and Background (B). Geni series support to quickly increase the basic magnification by 2 times, Select the required calibration mode in the Main Menu. 3 times or 4 times, as well as to return to the basic magnification.
  • Page 16: Video Recording

    InfiRay Outdoor • Geni Series• Operating Manual www.infirayoutdoor.com The image freezes for 0.5 sec with Tips: - You can enter and navigate the menu during video recording. a camera icon appears on - Recorded photos and videos are saved in built-in memory card of the the upper left corner of screen.
  • Page 17: Memory Access

    9. Wi-Fi Status ( : Wi-Fi off; : Wi-Fi on) 10. Clock (set clock in the App “InfiRay Outdoor” or the Main Menu) 11. IBP-2 Battery Pack status The status bar is at the top of the screen and shows information on the 12.
  • Page 18 InfiRay Outdoor • Geni Series• Operating Manual www.infirayoutdoor.com Icon Color/Status Battery Status among White Hot, Black Hot, Red Hot, Pseudo Color and Target Green more than 40% Highlighting mode. ⚫ Display Brightness: short press the M (5) button to change...
  • Page 19 InfiRay Outdoor • Geni Series• Operating Manual www.infirayoutdoor.com Main Menu ➢ Automatic exiting from the main menu to the home screen will occur after 15 seconds of inactivity. ➢ Enter the main menu with a long press of the M (5) button in home ➢...
  • Page 20 InfiRay Outdoor • Geni Series• Operating Manual www.infirayoutdoor.com Turn Wi-Fi on/off Wi-Fi ⚫ Press and hold down the M (5) button to enter the Main Menu. ⚫ Select the Wi-Fi menu option with the Up (6) / Down (4) button.
  • Page 21: Motion Sensor

    InfiRay Outdoor • Geni Series• Operating Manual www.infirayoutdoor.com Turn on/off the digital Compass function ⚫ Press and hold down the M (5) button to enter the Main Menu. Compass ⚫ Select the Compass menu option with the Up (6) / Down (4) button.
  • Page 22: Reticle Color

    InfiRay Outdoor • Geni Series• Operating Manual www.infirayoutdoor.com ⚫ Select one of three Profiles (marked with the letters A, B, C) with a short press of the Up (6) / Down (4) button. ⚫ Briefly press of the M (5) button to confirm your selection.
  • Page 23 ⚫ Confirm your selection with a short press of the M (5) button. To zero your riflescope, you need to set a zeroing profile and zeroing distance first. Geni series support the zeroing distance in the range of 1 to 999 m.
  • Page 24 InfiRay Outdoor • Geni Series• Operating Manual www.infirayoutdoor.com ⚫ Keep the reticle center the aiming point, then press and hold down the UP (4) and Down (4) button at the same time until a symbol of freeze appears on the left of the screen, and the image is frozen.
  • Page 25 InfiRay Outdoor • Geni Series• Operating Manual www.infirayoutdoor.com ⚫ The new zeroing distance appears in the status bar at the top of the display. Set standby status and time ⚫ Press and hold down the M (5) button to enter the Main Menu.
  • Page 26 Defect pixels are pixels that do not change brightness compare with others on the image, they are either brighter or darker than surrounding pixels. Geni series offer the possibility of removing any defective pixels on the sensor using software, as well as to cancel any deletion.
  • Page 27 InfiRay Outdoor • Geni Series• Operating Manual www.infirayoutdoor.com move ten pixels once. ⚫ Press the M (5) button briefly to switch the direction between X-axis and Y-axis. ⚫ Delete the defective pixel with a short press of the Power (7) button When the pixel has been successful deleted, the Add message will appear on the PIP window for a short time.
  • Page 28: Date Setting

    InfiRay Outdoor • Geni Series• Operating Manual www.infirayoutdoor.com Calibration ⚫ Press and hold down the M (5) button to enter the Main Menu. ⚫ Select the Compass Calibration menu option with the Up (6) / Down (4) button. ⚫ Briefly press the M (5) button to enter the Compass Calibration submenu.
  • Page 29: Time Setting

    ⚫ Select the desired language with a short press of the Up (6) / Down (4) button. Geni series support English and Russian two languages. ⚫ Confirm your selection with a short press of the M (5) button. ⚫ Submenu exit will take place automatically.
  • Page 30: Factory Reset

    InfiRay Outdoor • Geni Series• Operating Manual www.infirayoutdoor.com Units of measurement selection ⚫ In the Settings submenu, select the Unit menu option with the Up (6) / Down (4) button. ⚫ Enter the Unit submenu with a short press of the M (5) button.
  • Page 31 InfiRay Outdoor • Geni Series• Operating Manual www.infirayoutdoor.com ⚫ Confirm your selection with a short press of the M (5) button. ⚫ The riflescope will reboot If Yes is selected. ⚫ If No is selected, the action will be cancelled and will return to the submenu.
  • Page 32: Pip Function

    Stadiametric Rangefinder ➢ In the home screen, long press Up (6) button to enter the range Geni series is equipped with a stadiametric rangefinder, which allows you notification interface. to estimate the approximate distance to an object, if its size is known.
  • Page 33 Wi-Fi Function Status Bar Hiding Geni series Is built-in Wi-Fi module for wireless communication with mobile This function enables to show or hide the GUI information in the interface devices (smartphone or tablet).
  • Page 34 Set Wi-Fi Name and Password to the smartphone or tablet via Wi-Fi in real time mode. The Wi-Fi name and password of Tube series can be reset in the InfiRay You can find detailed instructions on InfiRay Outdoor in the separate Outdoor application.
  • Page 35: Technical Inspection

    InfiRay Outdoor • Geni Series• Operating Manual www.infirayoutdoor.com www.infirayoutdoor.com. ➢ After finishing the update, the device will root. ➢ Instructions for using InfiRay Outdoor can also be downloaded from the About InfiRay Outdoor official website. ➢ You can get InfiRay Outdoor...
  • Page 36: Troubleshooting

    InfiRay Outdoor • Geni Series• Operating Manual www.infirayoutdoor.com the following steps: non-greasy organic solvent. ➢ Wipe the external surface of metal and plastic parts off dust with a cotton ➢ Check the optics of the lens and the eyepiece. If necessary, remove the cloth.
  • Page 37 InfiRay Outdoor • Geni Series• Operating Manual www.infirayoutdoor.com fuzzy. There is dust or condensate on the interior or Wipe off the outside optical surfaces with a soft cotton cloth. Let the exterior optical surfaces of the lens. riflescope dry by leaving it in a warm environment for 4 hours.
  • Page 38 InfiRay Outdoor • Geni Series• Operating Manual www.infirayoutdoor.com between device and the smartphone or tablet (such as concrete wall). Image quality is too low or the These problems may occur due to the weather condition, such as snow, rain, fog etc.
  • Page 39: Legal And Regulatory Information

    InfiRay Outdoor • Geni Series• Operating Manual www.infirayoutdoor.com Legal and Regulatory Information including interference that may cause undesired operation. Information to the user Wireless transmitter module frequency range: Any Changes or modifications not expressly approved by the party WLAN: 2.412-2.472GHz (For EU) responsible for compliance could void the user's authority to operate the Wireless transmitter module power<20dBm (only for EU)
  • Page 40 InfiRay Outdoor • Geni Series• Operating Manual www.infirayoutdoor.com the interference by one or more of the following measures: - Reorient or relocate the receiving antenna. - Increase the separation between the equipment and receiver. - Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.