One heating zone is 
not reaching setpoint 
and another heater is 
overheating. 
Setpoint is reached 
but slightly off in 
temperature. 
Heater platen is 
overheating. 
Upper heater not 
coming down parallel 
to the lower platen. 
 
Upper platen falling 
down or lost 
tension. 
 
 
 
 
 
Sensors maybe crossed. 
Offset may need to be calibrated and 
adjusted. 
1. The mechanical Relay may be 
stuck in the closed position (zone 1, 
lower platen #1 labeled on this relay, 
zone 2, left upper and zone 3, right 
upper). 
 
2. If you are receiving 12vdc on the 
coil of the relay, the controller is 
properly functioning. 
 
Parallel lever not attached either in 
the rear out on the upper heater 
platen. Check to see if parallel leveler 
is connected on both sides. The 
retaining clip attached to pin may 
have come off. 
The springs have lost some 
tension. 
 
Make sure each sensor is 
connected to its prospective 
position on the terminal block 
and back to the controller. 
 
Call (800) 624-6717 for 
instructions. 
Use an Ohm meter for a 
continuity check must check at 
the cold pins of the heater (where 
the heater wire is brazed at 
the cold pin. This will eliminate 
any other failure before the 
heater element validating the loss 
off continuity at the source the 
heater element. 
Reconnect the pin and the 
retaining E-Clip. 
 
Remove rear panel and adjust the 
retaining collars on shaft by 
winding the spring tighter. There 
are multiple set screws that need 
to be loosened in order to wind 
the spring tighter. Once proper 
tension is achieved, tighten all set 
screws to prevent tension loss. 
 
 
 
 
 
 
---- 
---- 