your right control settings. If you desire a
separate left timer you can manually adjust
the left side timer without affecting the right
timer.
C L E A N C Y C L E
Start Cycle
To start a clean cycle, push CLEAN button
once so the CLEAN LED light is turned on. All
preset LED's are turned off, and the
temperature set point is changed to the clean
set point of 275°F. This also initiates the cool
down to clean set point condition as well the
display starts flashing until the clean set
point is reached.
Stop Cycle
To stop the clean cycle, simply press the
CLEAN button once to deactivate the clean
cycle. The CLEAN LED is turned off, the
preset LED's are restored, the temperature
set point is changed to the main set point.
Again, the warm-up condition is initiated and
the display flashes until the cook set point is
reached.
Change Clean Temp
275°F is the factory default temp for the
CLEAN cycle. To change the CLEAN cycle
temp, simultaneously hold down the TEMP
and CLEAN buttons for 15 seconds. The
current temp setting will display on the right
digital display only. Using the up or down
arrows to adjust to the desired temp.
P R E V E N T A T I V E
M A I N T E N A N C E
Proluxe machines are relatively
maintenance-free. For a long lifespan, the
following preventative maintenance should
be followed:
Daily Care:
1. Platens: Turn your machine off and allow
to cool down before attempting to clean.
These platens should only be cleaned with
mild soap and warm water then wiped off
with a clean, soft cloth or soft sponge.
2. E xterior surfaces: Wipe daily with mild
soap and warm water.
DO NOT use ice or cold water to cool the
unit down. This can cause platens to warp.
Service Problems:
Contact our factory at (800) 624-6717 (U.S.
only) or approved service agency. When
contacting the factory for information, parts
or service instructions, please provide the
serial number of the machine be provided.
This number can be found on the serial plate
located on the rear of the machine.
4