Proluxe CS157 Operation Manual page 7

Vantage light - single lid clamshell grill
Table of Contents

Advertisement

or randomly erratic. 
If when turning on, 
the display will first 
go to segment check 
Digital controller is 
constantly beeping. 
No heat on either on 
left, right, upper, or 
lower platen. 
 
 
 
Digital display shows 
PROB. No heat on 
any platen. 
 
Digital controller 
beeping and is 
overheating. 
 
Either platen is not 
heating but the 
digital controller is 
on and appears to be 
functioning. 
Beeper is not 
functioning. 
One of the three 
heater platens not 
close to set point. 
 
2. Control needs to reset. 
Sensor in one of two zones lost its 
continuity. Depress TEMP. While 
depressing TEMP depress either up 
or down arrow to locate error 
message PROB (zone 1, lower 
platen, zone 2 left upper platen, zone 
3, right upper platen.) If occurred 
when depressing the up arrow 
indicates either the left or right 
platen has the open sensor or 
Probe. 
 
Sensor lost it's continuity as shown 
on a muti-meter. 
The mechanical relay on the switched 
side is not opening to regulate 
temperature. Hold TEMP button 
then depress either the down or up 
arrow (zone 1, lower platen, zone 2, 
left upper platen and zone 3, right 
upper platen.) RLY will display on 
problem zone indicating the damage. 
 
If the mechanical relay(s) on the coil 
side are receiving 12vdc indicates the 
controller is functioning properly. If 
there is no voltage on the switching 
side of the relay to the heaters, the 
relay is not working properly. 
 
Beeper has failed. 
The offset function in the controller's 
setting needs to be adjusted to 
achieve proper shade of toast. 
 
2. While the unit is on unplug unit, 
wait for 1 min. Then plug machine 
on again and depress the power 
button. 
 
Disconnect probe and check for 
continuity (by using Ohm Meter) 
and replace. Do not cut and splice 
new sensor. Install new 2000 
ohm RTD sensor to underside of 
the platen and reconnect to 
controller. Upper left and right 
sensor for replacement on upper 
platens, lower platen sensor for 
replacement for lower platen. 
 
Disconnect prob that is open (no 
continuity as shown on a multi- 
meter. Must replace sensor 
(RTD). Do not cut and splice new 
sensor. Install a new 2000 ohm 
RTD sensor to under side of heat 
platen and reconnect to the 
controller. 
Replace the mechanical relay. 
 
Replace the mechanical relay. 
Replace control board. 
Call (800) 624-6717 for 
instructions. 
 
 
---- 
22 
46 
41 
15 
15 
A8 
---- 

Advertisement

Table of Contents
loading