Replacing a Boot-Optimized M.2 RAID Controller Module

Replacing a Boot-Optimized M.2 RAID Controller Module
The Cisco Boot-Optimized M.2 RAID Controller module connects to the mini-storage module socket on the
motherboard. It includes slots for two SATA M.2 drives, plus an integrated 6-Gbps SATA RAID controller
that can control the SATA M.2 drives in a RAID 1 array.

Cisco Boot-Optimized M.2 RAID Controller Considerations

Review the following considerations:
• This controller supports RAID 1 (single volume) and JBOD mode.
• A SATA M.2 drive in slot 1 (the top) is the first SATA device; a SATA M.2 drive in slot 2 (the underside)
• When using RAID, we recommend that both SATA M.2 drives are the same capacity. If different
Cisco UCS X210c M6 Compute Node Installation and Service Note
64
is the second SATA device.
• The name of the controller in the software is MSTOR-RAID.
• A drive in Slot 1 is mapped as drive 253; a drive in slot 2 is mapped as drive 254.
capacities are used, the smaller capacity of the two drives is used to create a volume and the rest of the
drive space is unusable.
JBOD mode supports mixed capacity SATA M.2 drives.