Page 1
This product has been Spec Sheet discontinued Cisco UCS C210 M2 General-Purpose Rack-Mount Server ISCO YSTEMS UBLICATION ISTORY 170 W ASMAN , CA, 95134 A.13 25, 2014 PRIL CISCO...
OVERVIEW OVERVIEW The Cisco® UCS C210 M2 server is a general-purpose, two-socket, two rack-unit (2RU) rack server that builds on the success of the UCS C210 M1 server. The UCS C210 M2 server (shown in Figure 1) extends the capabilities of the Cisco Unified Computing System™. The server uses Intel's latest Xeon 5600 Series multicore processors with 12 DIMM slots, 5 PCIe slots, embedded dual-port gigabit Ethernet controller, and up to 16 2.5-inch SAS/SATA hot-swappable hard disk drives (HDDs) or solid-state drives (SSDs).
DETAILED VIEWS DETAILED VIEWS Chassis Front View Figure 2 shows the Cisco UCS C210 M2 General-Purpose Rack Server. Figure 2 Chassis Front View Locator LED/Locator Button Memory fault LED Network Activity LED Power supply fault LED System fault LED Console connector (with supplied KVM cable, provides DB15 video, DB9 serial, and two USB 2.0 connectors)
32-bit color depth ■ 8 MB video memory ■ Internal storage devices Up to 16 2.5-inch SAS or SATA hot-swappable hard disk drives (HDDs) or ■ solid state drives (SSDs) USB socket on motherboard ■ Cisco UCS C210 M2 General-Purpose Rack-Mount Server...
Page 7
Power supply: Each power supply is equipped with a fan. ■ Integrated management Cisco Integrated Management Controller (CIMC) (with integrated video, KVM processor redirection, Security Intelligence Operations (SIO), fan speed control, Platform Environment Control Interface (PECI), and voltage monitoring) Cisco UCS C210 M2 General-Purpose Rack-Mount Server...
Table 2 PID of the Base C210 M2 Rack Server Product ID (PID) Description R210-2121605W UCS C210 M2 Srvr w/1PSU, w/o CPU, mem, HDD, DVD or PCIe card The R210-2121605W base server: Includes one power supply. ■ Does not include CPU, memory, hard disk drives (HDDs), Solid-State Drives (SSDs), plug-in ■...
DIMMs, the DIMMs will be clocked at the lower speed of 1066 MHz. Selecting higher-speed DIMMs: If you use 1333-MHz DIMMs with an E5620 CPU (which can support up to 1066-MHz DIMMs), the DIMMS will be clocked at the lower speed of 1066 MHz. Cisco UCS C210 M2 General-Purpose Rack-Mount Server...
Page 11
DIMMs, the DIMMs will be clocked at the lower speed of 1066 MHz. Selecting higher-speed DIMMs: If you use 1333-MHz DIMMs with an E5506 CPU (which can support up to 800-MHz DIMMs), the DIMMS will be clocked at the lower speed of 800 MHz. Cisco UCS C210 M2 General-Purpose Rack-Mount Server...
Page 12
For optimal performance, select DIMMs with the highest clock speed for a given processor ■ (see Table 5 on page 14). If you select DIMMs whose speeds are lower or higher than that shown in the tables, suboptimal performance will result. Cisco UCS C210 M2 General-Purpose Rack-Mount Server...
DDR3 ECC registered DIMMs (RDIMMs), supporting Intel SDDC ■ Memory is organized with three memory channels per CPU, with up to two DIMMs per ■ channel (DPC), as shown in Figure Figure 4 C210 M2 Memory Organization Cisco UCS C210 M2 General-Purpose Rack-Mount Server...
Page 14
1 DIMM in Channel A, 1 DIMM in Channel B 2 DIMMs in Channel A, 2 DIMMs in Channel B Choose the memory mirroring option (N01-MMIRROR) as shown in Table 5 on page ■ Cisco UCS C210 M2 General-Purpose Rack-Mount Server...
Page 15
Memory mirroring: ■ If you choose the Memory RAS option, be aware that it is available only with an even number of memory channels. For example, if you choose six DIMMs and select RAS, Cisco UCS C210 M2 General-Purpose Rack-Mount Server...
Page 16
4-GB and two 8-GB DIMMs. One 4-GB/8-GB DIMM pair would located on Channel A of CPU 1, and one 4-GB/8-GB DIMM pair would be located on Channel B of CPU 1. For more information regarding memory, see CPUs and DIMMs on page Cisco UCS C210 M2 General-Purpose Rack-Mount Server...
PCIe RAID controller card. Cisco can provide factory-configured RAID 0, 1, 1E, 5, 6, and 10 systems depending on the RAID implementation chosen and the number of drives ordered. Factory-configured RAID options are...
Page 18
Enable RAID 10 Setting. Requires an even number of drives (minimum 4 drives) of same size, speed, capacity. NOTE: No RAID option can be chosen if you have one of the following configurations: • A mix of SAS and SATA drives • No drives Cisco UCS C210 M2 General-Purpose Rack-Mount Server...
Page 19
You can choose an optional RAID configuration (RAID 0, 1, 5, 6, or 10), which is ■ pre-configured at the factory. If you do not choose a RAID configuration, the disks will be configured as a JBOD. Cisco UCS C210 M2 General-Purpose Rack-Mount Server...
If you do not select a SAS Expander, the SAS Extender comes standard with the UCS C210 M2 server chassis. The SAS Extender supports up to eight disk drives. The SAS Extender option is not field upgradeable to a SAS Expander.
Page 24
— Only a single Cisco UCS P81E Virtual Interface Card/ 2-port 10Gbp card may be installed and it must be installed in slot 1 or slot 2. Note, however, that if the server is running UCSM, only slot 1 is supported for the VIC card. See Figure 3 on page 5 for slot numbering.
Caveats The twinax cables listed in Table 10 can be ordered only for the following PCIe cards: — N2XX-ACPCI01 (Cisco UCS P81E Virtual Interface Card/ 2-port 10Gbps) — UCS-PCIE-BSFP (Broadcom 57712) — N2XX-ABPCI02 (Broadcom 57711) —...
Page 26
Table 11 should be ordered only for the following PCIe cards, as they do not come by default with any optical modules: — N2XX-ACPCI01 (Cisco UCS P81E Virtual Interface Card/ 2-port 10Gbps) — UCSC-PCIE-BSFP (Broadcom 57712) — N2XX-ABPCI02 (Broadcom 57711) —...
Page 27
CONFIGURING the SERVER Figure 5 Network Card Connections Cisco UCS C210 M2 General-Purpose Rack-Mount Server...
An optional DVD-RW optical drive, with dual-layer (DL) media support, may be ordered. The drive is listed in Table Table 12 Available DVD-RW Drive Product ID (PID) PID Description R210-ODVDRW DVD-RW Drive for UCS C210 M2 Rack Servers Cisco UCS C210 M2 General-Purpose Rack-Mount Server...
One 650 W power supply ships with the base server chassis. You can order an optional redundant power supply listed in Table 13s. Table 13 Redundant Power Supply Product ID (PID) PID Description R2X0-PSU2-650W-SB 650 W power supply, w/added 5A Standby for UCS C200 or C210 Cisco UCS C210 M2 General-Purpose Rack-Mount Server...
EL 701 (IEC60320/C13) CAB-9K10A-AU Power Cord, 250VAC 10A 3112 Plug, Australia Cordset rating: 10 A, 250 V/500 V MAX Length: 2500mm Connector: EL 701C Plug: EL 210 (EN 60320/C15) (BS 1363A) 13 AMP fuse Cisco UCS C210 M2 General-Purpose Rack-Mount Server...
Page 31
Power Cord, 250VAC 10A BS1363 Plug (13 A fuse), UK Cordset rating: 10 A, 250 V/500 V MAX Length: 2500mm Connector: Plug: EL 701C EL 210 (EN 60320/C15) (BS 1363A) 13 AMP fuse Cisco UCS C210 M2 General-Purpose Rack-Mount Server...
Page 32
Table 14 Available Power Cords (continued) Product ID (PID) PID Description Images CAB-9K12A-NA Power Cord, 125VAC 13A NEMA Image not available 5-15 Plug, North America CAB-JPN-3PIN Power Cord 3PIN, Japan Image not available Cisco UCS C210 M2 General-Purpose Rack-Mount Server...
CONFIGURING the SERVER STEP 12 ORDER TOOL-LESS OPTIONAL RAIL KIT A rail kit is not included with the Cisco UCS C210 M2 base server chassis, but you can order the tool-less rail kit listed in Table 15). Table 15 Rail Kit...
Product ID (PID) PID Description R2XX-CMAG3-1032 Cable Mgmt Arm for R2XX-G31032RAIL for C200/C210 For more information about the cable management arm, see the Cisco UCS C210 Installation and Service Guide at this URL: http://www.cisco.com/en/US/docs/unified_computing/ucs/c/hw/C210M1/install/C210M1.html Cisco UCS C210 M2 General-Purpose Rack-Mount Server...
MSWS-12-ST2S Windows Server 2012 Standard (2 CPU/2 VMs) MSWS-12-DC2S Windows Server 2012 Datacenter (2 CPU/Unlimited VMs) MSWS-12-ST2S-NS Windows Server 2012 Standard (2 CPU/2 VMs) No Cisco SVC MSWS-12-DC2S-NS Windows Server 2012 Datacenter (2 CPU/Unlim VM) No Cisco SVC SUSE SLES-SVR-2S-1G-1A SUSE Linux Enterprise Srvr (1-2 CPU,1 Phys);1yr Support Reqd...
Page 37
VSG-VLEM-UCS-1 VSG License Paper Delivery (1 CPU) for bundles UCS Director CUIC-PHY-SERV-BM-U Cisco Cloupia Resource Lic - One Phy Server node bare metal CUIC-PHY-SERV-U Cisco Cloupia Resource Lic - One physical Server node CUIC-TERM Acceptance of Cisco Cloupia License Terms...
Page 38
VMware vCenter 5 Server Standard, 3 yr support required VMW-VC5-STD-4A VMware vCenter 5 Server Standard, 4 yr support required VMW-VC5-STD-5A VMware vCenter 5 Server Standard, 5 yr support required UCS-VMW-TERMS Acceptance of Terms, Standalone VMW License for UCS Servers Cisco UCS C210 M2 General-Purpose Rack-Mount Server...
Windows Svr 2008 R2 EN (1-8CPU, 25CAL), Media MSWS-08R2-DCHV-RM Windows Svr 2008 R2 DC (1-8CPU, 25CAL), Media MSWS-12-ST2S-RM Windows Server 2012 Standard (2 CPU/2 VMs) Recovery Media MSWS-12-DC2S-RM Windows Server 2012 Datacenter (2 CPU/Unlimited VM) Rec Media Cisco UCS C210 M2 General-Purpose Rack-Mount Server...
UCSM upgrades. The Unified Computing Support Service includes flexible hardware replacement options, including replacement in as little as two hours. There is also access to Cisco's extensive online technical resources to help maintain Cisco UCS C210 M2 General-Purpose Rack-Mount Server...
Page 41
Warranty Plus provides remote access any time to Cisco support professionals who can determine if a return materials authorization (RMA) is required. You can choose a...
Page 42
With the Cisco Unified Computing Drive Retention (UCDR) service, you can obtain a new disk drive in exchange for a faulty drive without returning the faulty drive. In exchange for a Cisco replacement drive, you provide a signed Certificate of Destruction (CoD) confirming that the drive has been removed from the system listed, is no longer in service, and has been destroyed.
Page 43
24x7x4 Onsite CON-UCWD7-R210WSFF UCWD8 24x7x2 Onsite CON-UCWD8-R210WSFF For more service and support information, see the following URL: http://www.cisco.com/en/US/services/ps2961/ps10312/ps10321/Cisco_UC_Warranty_Support_DS.pdf For a complete listing of available services for Cisco Unified Computing System, see this URL: http://www.cisco.com/en/US/products/ps10312/serv_group_home.html Cisco UCS C210 M2 General-Purpose Rack-Mount Server...
OPTIONAL STEP - ORDER RACK(s) OPTIONAL STEP - ORDER RACK(s) The optional R42610 rack is available from Cisco for the C-Series servers, including the C210 M2 server. This rack is a standard 19-inch rack and can be ordered with a variety of options, as...
OPTIONAL STEP - ORDER PDU OPTIONAL STEP - ORDER PDU An optional power distribution unit (PDU) is available from Cisco for the C-Series rack servers, including theC210 M2 server. This PDU is available in a zero rack unit (RU) style (see Table 24).
SUPPLEMENTAL MATERIAL SUPPLEMENTAL MATERIAL CHASSIS An internal view of the C210 M2 chassis with the top cover removed is shown in Figure Figure 6 C210 M2 With Top Cover Removed Cisco UCS C210 M2 General-Purpose Rack-Mount Server...
CPU 1, for example, it must be located in slot 2 (A1, channel A, bank 1); likewise, if only one DIMM is used for CPU 2, it must be installed in slot 2 (D1, channel D, bank 1). Figure 7 CPU DIMM Channels and Banks Cisco UCS C210 M2 General-Purpose Rack-Mount Server...
That is, the server cannot operate in Power Saving Mode unless all DIMMs are low-voltage DIMMs. CPUs that have a maximum memory frequency less than 1333 MHz support low-voltage ■ DIMMs operating in Power Saving Mode only, and do not support Performance Mode. Cisco UCS C210 M2 General-Purpose Rack-Mount Server...
SUPPLEMENTAL MATERIAL Configuration Samples The following figures show examples of how DIMMs are populated for 1-CPU and 2-CPU systems. Figure 8 Example of 24-GB DIMM Memory Combinations with One CPU Cisco UCS C210 M2 General-Purpose Rack-Mount Server...
Page 51
SUPPLEMENTAL MATERIAL Figure 9 Example of 96 GB DIMM Memory Combinations with Two CPUs Cisco UCS C210 M2 General-Purpose Rack-Mount Server...
NOTE: The SAS expander is a factory-configurable option in this server. The expander is field-replaceable. The SAS Expander has two mini-SAS SFF-8087 cable connectors. One connector provides connection for up to 16 drives, and the second connector provides redundancy. Cisco UCS C210 M2 General-Purpose Rack-Mount Server...
SUPPLEMENTAL MATERIAL RACKS The Cisco R42610 rack (see Figure 12) is certified for Cisco UCS installation at customer sites and is suitable for the following equipment: Cisco UCS B-Series servers and fabric interconnects ■ Cisco UCS C-Series and select Nexus switches ■...
Page 54
SUPPLEMENTAL MATERIAL Figure 12 Cisco R42610 Rack Front view - door closed Front view - door open Front view - door removed Cisco UCS C210 M2 General-Purpose Rack-Mount Server...
With a Cisco RP Series PDU in the rack, you can replace up to two dozen input power cords with just one. The fixed input cord connects to the power source from overhead or under-floor distribution. Your IT equipment is then powered by PDU outlets in the rack using short, easy-to-manage power cords.
SUPPLEMENTAL MATERIAL POWER SUPPLIES The C210 M2 can accommodate one or two 650 W power supplies. A typical power supply is shown in Figure Figure 14 C210 M2 Power Supply Cisco UCS C210 M2 General-Purpose Rack-Mount Server...
Product ID (PID) PID Description 37-1016-01 KVM Cable Figure 15 KVM Cable Connector (to server front panel) VGA connector (for a monitor) DB-9 serial connector Two-port USB connector (for a mouse and keyboard) Cisco UCS C210 M2 General-Purpose Rack-Mount Server...
SUPPLEMENTAL MATERIAL Motherboard USB Port The C210 M2 motherboard has a general-purpose USB socket, as shown in Figure Figure 16 Motherboard USB Port Cisco UCS C210 M2 General-Purpose Rack-Mount Server...
TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS Dimensions and Weight Table 29 UCS C210 M2 Dimensions and Weight Parameter Value Height 3.45 in. (8.76 cm) Width 17.39 in.(44.17 cm) Depth 28.35 in. (72.01 cm) Front Clearance 3 in. (7.62 cm) Side Clearance 1 in. (2.54 cm) Rear Clearance 6 in.
Page 60
TECHNICAL SPECIFICATIONS NOTE: AC input connector is an IEC 320 C-14 15A/250VAC power inlet. For configuration-specific power specifications, use the Cisco UCS Power Calculator at this URL: http://www.cisco.com/assets/cdc_content_elements/flash/dataCenter/cisco_ucs_power_calculator/. As an example, using the calculator, we can determine the approximate power for the following C210 M2...
TECHNICAL SPECIFICATIONS Environmental Specifications The power specifications for the C210 M2 server are listed in Table Table 31 UCS C210 M2 Environmental Specifications Parameter Minimum Temperature operating 10°C to 35°C (50°F to 95°F) Temperature nonoperating -40°C to 65°C (-40°F to 149°F) Altitude operating 0 to 3,000 m (0 to 10,000 ft.);...
47CFR Part 15 (CFR 47) Class A AS/NZS CISPR22 Class A CISPR22 Class A EN55022 Class A ICES003 Class A VCCI Class A EN61000-3-2 EN61000-3-3 KN22 Class A CNS13438 Class A EMC - Immunity EN55024 CISPR24 EN300386 KN24 Cisco UCS C210 M2 General-Purpose Rack-Mount Server...