Unexpected behaviour

Problem
The power level selec-
ted is flashing.
Power level 9 is auto-
matically reduced if you
also set power level 9
for the connected cook-
ing zone.
A cooking zone
switches off automatic-
ally.
The cooking zone is not
working in the usual
way on the power set-
ting selected.
A cooking zone or the
whole hob switches off
automatically.
The Booster has deac-
tivated early automatic-
ally.

Unsatisfactory results

Problem
The food in the pan
does not heat up when
the Auto heat-up func-
tion is switched on.
Cause and remedy
There is no pan on the cooking zone, or the pan is
unsuitable.
 Use suitable pans (see "Induction - Pans").
Operating both zones at power level 9 exceeds the
permitted maximum power for the two zones.
 Use a different cooking zone.
It has been operated for too long.
 You can use the cooking zone again by switching
it back on (see "Safety switch-off").
The overheating protection mechanism has been ac-
tivated.
 See "Safety features".
The overheating protection mechanism has been ac-
tivated.
 See "Safety features".
The overheating protection mechanism has been ac-
tivated.
 See "Safety features".
Cause and remedy
A large amount of food is being heated up.
 Start cooking at the highest power level and then
turn down to a lower one manually later on.
The pan is not conducting heat properly.
 Use a different pot or pan which conducts heat
properly.