ORiNG IBS-102FX Series Quick Installation Manual

ORiNG IBS-102FX Series Quick Installation Manual

Industrial optical bypass switch

Advertisement

Quick Links

BYPASS
SWITCH
Q
I
uick
nstallation
I N D U S T R I A L
Introduction
IBS-102FX series
are external Bypass switches for 100M/1G/10G fiber
optical networks. These fiber optical bypass switches protect the network
from failures and Network maintenance by ensuring network integrity during
power loss. Each of these optical bypass switches includes Network ports
and Monitor ports.
The Network ports are used for connection to main-
network connections and provide protection mechanism, and the Monitor
ports are used for down-link local networking device. When the power is on,
the operating mode of the Bypass switch is set to Normal , and the local
networking device is connected with main-network.
occurs, the Bypass switch is swiftly set to bypass mode to isolate the main-
network from the local networking device.
Features
Support 100M/1G/10G optical bypass function of 2 port duplex or 4 port simplex
fiber connection
Different models supported for multi-mode or single-mode optical fiber
Low insertions loss
Throughput not affected and no extra delay
Bypass switching time < 8ms
Dual Wide range power inputs: 12~48VDC
Relay output for pwer failed warning
Rigid IP-30 housing design
Din-Rail/Wall-mount installation
Package Contents
The device is shipped with the following items. If any of these items is missing
or damaged, please contact your customer service representative for
assistance.
Contents
Pictures
IBS-102FX-MM-LC or
IBS-102FX-SS-LC
DIN-rail Kit
Wall-mount Kit
QIG
Preparation
Before you begin installing the switch, make sure you have all of the package
contents available.
Safety & Warnings
Elevated Operating Ambient: If installed in a closed cabinet, the operating
ambient temperature of the rack environment may be greater than room ambient.
Therefore, consideration should be given to installing the equipment in an
environment compatible with the maximum ambient temperature (Tma) specified by
the manufacturer.
Q I G
IBS-102FX Series
IBS-102FX Series
G
uide
Reduced Air Flow: Installation of the equipment should be such that the amount of
air flow required for safe operation of the equipment is not compromised.
Mechanical Loading: Mounting of the equipment in the d
a hazardous condition is not achieved due to uneven mechanical loading.
Circuit Overloading: Consideration should be given to the connection of the equipment to
the supply circuit and the effect that overloading of the circuits might have on overcurrent
protection and supply wiring. Appropriate consideration of equipment nameplate ratings
should be used when addressing this concern.
When power failure
Dimension
IBS -102FX
P1
100M /1G /10G bps
Number
26.1
X 1
Panel Layouts
Front Panel
X 1
2
IBS -102FX
1
3
P1
P2 Fault
X 2
Alarm
4
P1
P2
X 1
TX
A
RX
TX
B
RX
5
TX
A
RX
TX
B
RX
100M /1G /10G bps
1907-2-29-IBS102FX-2.1
in-rail
should be such that
Unit =mm (Tolerance ±0.5mm)
24.3
36.0
22.8
36.1
13.1
9.25
94.9
25.6
Ø3.0
8.5
Ø5.9
P2 Fault
Alarm
P1
P2
14.0
6.05
TX
A
RX
TX
B
RX
TX
A
RX
TX
B
RX
Top Panel
1
2
3
4
1. PWR1 LED
1A@24V
PWR2
PWR1
-
+
2. PWR2 LED
G
3. Fault LED
Relay
V+
V- DC12-48V
4. DIP-switch for power alarm
relay output
1
5. LC connector ports
Real Panel
1. Din-rail screw holes
1
PRINTED ON RECYCLED PAPER
Industrial Optical Bypass Switch
Installation
DIN-rail Installation
Step 1: Slant the switch and screw the Din-rail kit onto the back of the switch, right in the
middle of the back panel.
Step 2: Slide the switch onto a DIN-rail from the Din-rail kit and make sure the switch clicks into
the rail firmly.
25.0
Wall-mounting
Step 1: Screw the two pieces of wall-mount kits onto both sides of the switch. A
total of eight screws are required, as shown below.
Step 2: Use the switch, with wall mount plates attached, as a guide to mark the correct
locations of the four screws.
Step 3: Insert four screw heads through the large parts of the keyhole-shaped apertures, and
then slide the switch downwards. Tighten the four screws for added stability.
1. Wall-mount screw
holes
2. Terminal block
3. DC power input
4. Frame ground
Version 2.1
IBS -102FX
P1
P2 Fault
Alarm
P1
P2
TX
A
RX
TX
B
RX
TX
A
RX
TX
B
RX
100M /1G /10G bps
Quick Installation Guide

Advertisement

loading
Need help?

Need help?

Do you have a question about the IBS-102FX Series and is the answer not in the manual?

Questions and answers

Summary of Contents for ORiNG IBS-102FX Series

  • Page 1 Version 2.1 BYPASS IBS-102FX Series SWITCH Industrial Optical Bypass Switch uick nstallation uide I N D U S T R I A L Introduction Installation Reduced Air Flow: Installation of the equipment should be such that the amount of DIN-rail Installation...
  • Page 2 IEC60068-2-31 Alarm Specifications Vibration IEC60068-2-6 MTBF 1246758hrs Warranty 3 years IBS-102FX-SS-LC IBS-102FX-MM-LC ORing Bypass Switch Model Physical Ports 4 Duplex Single-mode LC 4 Duplex Multi-mode LC LC connector connector connector Fiber Ethernet Optical Fiber Single-mode: 9/125 m µ Multi-mode: 50/125µm or 62.5/125µm 1310 40, 1550 40 nm ±...