Download Print this page

Inspection Guidelines - MAAX AKER Assembly And Operation Manual

Advertisement

Bodywrap Whirlpool System
Assembly And Operation Guide

Inspection Guidelines

A carelful check of the whirlpool system
should be conducted upon receipt of the
unit. The basic whirlpool configuration is
shown in Figure 1. A system with an in-line
heater is shown in Figure 2.
If the unit has a factory-fitted:
Alternate pump location,
refer to the Supplemental Assembly
information packaged with the accessory
items for additional item checks before
continuing. Notify your supplier immediately if
any questions or problems are encountered
during this process.
DO NOT INSTALL UNIT WITHOUT
FIRST ADDRESSING QUESTIONS
WHICH ARISE DURING THE
INSPECTION!
Basic Whirlpool System Check
> Check to be certain the air hose is
secured to the on/off button and to the
whirlpool pump. It is possible that during
shipping and handling this air hose may
become loose. This hose must be
firmly in place on both the on/off button
and pump-motor, otherwise the pump
will not start.
Whirlpool System with Mounted In-Line
Heater Check
> Check for factory installed in-line heater
option mounted on pump.
> Check system to ensure all trim is in
place and for finish color ordered.
Installation Guidelines
Framing and Installation Requirements
Framing and dimensional requirements for
clearance of whirlpool fittings are included in
the installation guidelines with the basic unit.
Refer to clearance information for optional
components if present. This information is
provided in supplimental documents
provided with the whirlpool packaging.
WARNING!
ADEQUATE ACCESS MUST BE
PROVIDED AT THE PUMP LOCATION.
The basic whirlpool system is produced with
the pump secured to the unit base and the
complete system assembled at the factory.
Figure 1 - Basic Whirlpool System
(Typical Tub Illustrated)
Air Control Knob
(2 per unit)
Factory Installed
System Piping
Factory Mounted
Figure 2 - Whirlpool System With
In-Line Heater (Factory Installed Option)
Jet Supply
Line
Factory Mounted
Single-Speed Pump
-2-
Factory Connected
On/Of Control Air Hose
Unit Base
Electrical Supply Cable
With Attachment
Plug End.
Electrical Supply Cable With
Attachment Plug End.
(Pump/Motor)
On/Off Button
Jet Supply Line
Suction Line
Factory Mounted
Single-Speed
Pump
Jet Supply Line
Factory Mounted
In-Line Heater
Suction Line
Electrical Supply Cable With
Attachment Plug End.
(In-Line Heater)
10023064