Technical data
Parameter
EMC rating for the charge post
EMC rating for the power cabinet
7.3

Cleaning specifications

Parameter
Cleaning agent
Non-abrasive tool
7.4

Electrical installation specifications (North America)

Parameter
Upstream overcurrent protection device Fuse (gG type) 300 A
Surge protection device within the up-
stream power distribution system
Power consumption of the power cabi-
net
Power consumption of the charge post
Earthing rod (initial)
Earthing rod (additional)
Input AC power connection
Input grounding system
Input voltage range
Nominal input current
Power factor at full load
Efficiency
Maximum AC inrush current
7.5

Electrical installation specifications (Canada)

Parameter
Upstream overcurrent protection device Fuse (gG type) 250 A AC
Surge protection device
Power consumption of the power cabi-
net
40
Specification
FCC part 15 Class B (residential)
The power cabinet complies with Class A
(industrial).
If the power cabinet must comply with
Class B (residential), install an external
Schaffner type FN 3359HV-400-99 EMC
filter.
Specification
pH value between 6 and 8
Non-woven nylon hand pad
Specification
According to UL 1449
In standby status: ≤ 80 W
In standby status: ≤ 70 W
With the LEDs on: ≤ 145 W
Maximum 10 Ω
0.9 Ω
480/277 3W + PE
wye Grounded system
480 VAC +/- 10% (50 Hz or 60 Hz)
231 A at 480 V AC
0.97
≥ 94% at ≥ 20 % load
240 A for 20 ms at 480 VAC
Specification
Type 1 or Type 2, in accordance with UL
1449
In standby status: ≤ 80 W
9AKK107992A3070-EN | 003