Technical Specifications - ABB InCharge Terra AL2-40-240-T1-WC1R Installation Manual

Terra ac wallbox 40a / 48a / 80a level 2 charger
Table of Contents

Advertisement

Technical Specifications

Configuration
Voltage
AC Input Power Connection
Recommended breaker
Output Parameters
Voltage
Current - Max
Power - Max
Controls and Interface
Charging Connectors
Communication
Network Connection
RFID
Environment
Temperature - Operating
Temperature - Storage
Altitude - Operating
Protection - Intrusion
General
Cable Length
Safety and EMI
* Derating characteristics apply at extreme temperatures
GET IN TOUCH
818.697.GOEV
1433 Fifth Street, Santa Monica, CA 90401
hello@inchargeus.com | inchargeus.com
SKU
208-240 Vac
L1, L2, G
50A / 60A / 100A
Value
208/240 VAC, 50/60 Hz
40A / 48A / 80A
9.6 kW / 11.5 kw / 19.2kW
Value
SAE J1772, Type 1 cable, 25ft (7.6 m)
OCPP 1.6J, Modbus RTU RS485 (energy meter or local controller
connection), Modbus TCP/IP (local controller connection)
4G, LTE, WCDMA, Ethernet (RJ45) with daisy-chain Ethernet op-
tion, Wifi, Bluetooth, Modbus RTU RS485, Modbus TCP/IP
RFID Card Reader
Value
-40 °C to +55 °C (-40 °F to +131 °F)*
-40 °C to +85 °C (-40 °F to +185 °F)
4000 m (13,123 ft)
Indoor and Outdoor, NEMA 4; IP65, IK10
Value
25 ft
UL 2594, UL 2231-1, UL 2231-2, UL 1998, CSA C22.2. NO.280,
NMX-J-667-ANCE
©️2022 In-Charge US | All Rights Reserved