Problem
The EV crashed or is on
fire.
The EVSE or the connector
has visible damage.
The EVSE stops.
Coolant fluid leaks from
the cooled EV charge cable
9AKK107992A3070-EN | 003
Possible cause
A very dangerous situation
has occurred.
A possible dangerous sit-
uation has occurred
The sensors of the cooling
unit detect a problem, for
example an internal leak-
age of cooling fluid. The
EVSE stops automatically.
The cooled EV charge ca-
ble has damage.
Troubleshooting
Possible solution
1. Do not use the EVSE.
2. Disconnect the power
supply.
3. Make sure that all per-
sons keep a safe dis-
tance. Obey the local
rules.
4. Contact your local rep-
resentative of the
manufacturer. Refer to
section 1.12.
1. Do not use the EVSE.
2. Contact your local rep-
resentative of the
manufacturer. Refer to
section 1.12.
1. Tell a maintenance en-
gineer to empty the
overflow reservoir for
cooling fluid.
2. Schedule for the neces-
sary maintenance or
repairs.
3. If it is necessary, con-
tact your local repre-
sentative of the manu-
facturer. Refer to sec-
tion 1.12.
1. Do not use the EVSE.
2. Try to absorb the fluid
with a liquid absorbing
material, such as sand,
diatomaceous soil or
acid binding agent.
Obey the rules for cor-
rect disposal. Refer to
section 2.9.
3. Contact your local rep-
resentative of the
manufacturer. Refer to
section 1.12.
35