Installation; Technical Specifications - K4713-1 Cool Wave ™ 20S - Lincoln Electric Cool Wave 20S Operator's Manual

Table of Contents

Advertisement

COOL WAVE™ 20S
TECHNICAL SPECIFICATIONS -
K4713-1 COOL WAVE ™ 20S
INPUT POWER RATINGS
FREQUENCY
PHASE
VOLTAGE
50/60 HERTZ SINGLE
115 VAC
PUMP HYDRAULIC RATING
NO FLOW -
DISCHARGE PRESSURE (GAGE)
(RELIEF VALVE SETTING)
NO PRESSURE - FLOW RATE
TYPICAL OPERATION -
DISCHARGE PRESSURE (GAGE)
TYPICAL OPERATION -
FLOW RATE
RATED COOLING POWER
PER IEC-60974-2
*Cooling Power is measured at a 1 L/min. flow rate with a 40°C coolant temper-
ature rise in a 25°C (77ºF) environment.
DEGREE OF ENVIRONMENTAL PROTECTION
RESERVOIR CAPACITY
2.375 GALLONS (9.0 LITERS)
AGENCY COMPLIANCE
IEC-60974-2,
TEMPERATURE RANGE
9°F to 104°F (-13°C to 40°C)
RECOMMENDED COOLANT
DISTILLED OR DE-INOIZED WATER*
DO NOT USE: AUTOMOTIVE ANTI-FREEZE THAT CONTAINS RUST
INHIBITORS OR LEAK STOPPERS. THESE COOLANTS WILL
DAMAGE THE PUMP AND BLOCK THE SMALL INTERNAL
PASSAGEWAYS OF THE HEAT EXCHANGER, AFFECTING COOLING
PERFORMANCE.
*FOR SUB FREEZING APPLICATIONS
KP4159-1 Low Conductivity Coolant
Use 50-50 mix of coolant and water for freezing
protection down to 9°F (-13°C)
CURRENT
CURRENT
DRAW
DRAW
@ 60 HZ
@ 50 HZ
3.8 AMPS
4.0 AMPS
70 PSIG (414 KPA) (4.14 BAR)
MAX.
1.66 GAL/MIN (6.28 LITER/MIN)
MAX.
53-57 PSIG (365-393 KPA)
0.34 GAL/MIN (1.3 LITER/MIN)
2.00 KW @ 1.00 LITER/MIN
6824 BTU/HR @ .26 GAL/MIN
IP 23
CSA
,
C
US
PHYSICAL DIMENSIONS
LENGTH
WIDTH
30.70 IN
15.99 IN
14.93 IN
(78.0 CM)
(40.6 CM)
(37.9 CM)
EXPLANATION OF SYMBOLS THAT APPEAR ON THIS EQUIPMENT
ArcLink
®
STATUS
A-1

INSTALLATION

WEIGHT W/
SHIPPING
HEIGHT
RESERVOIR
WEIGHT
FULL
92 LB
114 LB
(41.7 KG)
(51.7 KG)
COOLANT
OUT
COOLANT
IN

Hide quick links:

Advertisement

Table of Contents
loading