Technical specifications
7.4 Technical data
7.4.2
Ambient conditions
Climatic ambient conditions
For permitted mounting positions, see section Preparing for installation (Page 18).
Temperature, tested in accordance with IEC 60068-2-1, IEC 60068-2-2 and IEC 60068-2-14
Operation, x6413E, without M.2 Module
Operation, x6413E, M.2 Module load max. 5W 0 °C to +50 °C applies to device for horizontal mount-
Temperature during storage/transport
Gradient
Relative humidity, tested in accordance with IEC 60068-2-78, IEC 60068-2-30
Operation
Storage/transport
Atmospheric pressure
Operation
Storage/transport
Multiplication factors for equipment ambient temperature of operation at altitudes up to
3000m, tested in accordance with IEC 61131-2:2017
Altitude
0 to 2000 m
3000 m
Equipment ambient temperature rating at 2000 m.
1
Atmospheric pressure and air density increases with decreasing altitude. Therefore utiliza-
2
tion of the derating factor for 0 m to 2000 m for altitudes below sea level is considered
conservative.
Mechanical ambient conditions
Vibration resistance, tested in accordance with IEC 60068-2-6
Operation
62
2
0 °C to +55 °C applies to device for horizontal mount-
ing positions
ing positions
-20 °C to +70 °C
•
Operation: Max. 10 °C/h
•
Storage: 20 °C/h, no condensation
8% to 85% at 30 °C, no condensation
Gradient ≤ 10℃/h
8% to 90% at 25/55 °C, no condensation
Gradient ≤ 20℃/h
1080 to 627 hPa, corresponds to an altitude of -1000
to 3000 m
1080 to 660 hPa, corresponds to an altitude of -1000
to 3500 m
Derating ratio for temperature
1.0
0.9
Except DIN-Rail:
•
5 to 8.4 Hz: 3.5 mm
•
8.4 to 500 Hz: 9.8 m/s²
DIN-Rail:
•
10 to 58 Hz: 0.0375 mm
•
58 to 200 Hz: 4.9 m/s²
Operating Instructions, 09/2021, A5E51366275-AA
1
SIMATIC IPC327G