Installation Requirements - ZKTeco Green Label Elite Series Quick Start Manual

Table of Contents

Advertisement

2

Installation Requirements

The installation requirements and indicators associated with the temperature detection is given
below:
Specification
Operating
Environment
Distance
(between face
and device)
Measurement
Accuracy
Notes: The temperature measurement data is for reference only, and not for any medical purpose.
Forehead Temperature Detection
Standard value
Indoor, No wind, No direct light,
20°C to 35°C (68°F to 95°F)
30cm to 120cm (0.98ft to 3.94ft)
±0.3°C (±0.54°F)
155CM
The recommended operating
temperature is 25°C (77°F)
The recommended distance
This value is tested at a distance
of 80cm or 2.63ft under 25°C or
Indoor constant Temperature
Environment
Installation height: 1.55m
FOV ( eld of view) of the thermal
imaging device: 50°
Temperature measurement
distance: 0.3m to 1.2m
Height of the face adapted for
detection: 1.2m to 2m
Installation Environment:
INSTALL INDOORS
AVOID INSTALLATION
ONLY
GLASS WINDOWS
2
Remark
is 80cm (2.62ft)
77°F environment.
AVOID DIRECT
NEAR
SUNLIGHT
AND EXPOSURE
AVOID USE OF ANY
HEAT SOURCE
NEAR THE DEVICE