Air Chamber
Fig. 26
ESP Probe
Fig. 27
Ash Breaker
Fig. 28
Cover
Loosen Wing Screws
Check for Fly Ash
Build-up Here.
5. Loosen wing screws and swing the burn pot clean
out cover to the side. Clean out the air chamber and
replace cover. See Figure 26.
6. Clean fly ash from flue area shown in fig. 27. Be
careful not to damage the ESP Probe.
Soot Build-up
Soot residue accumulates on the flue lining as the
products of combustion combine with moisture. This
occurs when coal is burned. When coal is ignited, the
soot residue creates an extremely hot fire.
During the heating season, both the chimney and
the chimney connector need to be inspected at least ev-
ery two months to determine if a soot build-up has oc-
curred.
Soot accumulation must be removed to reduce the
risk of a chimney fire.
Ash Breaker
The 44 Magnum is equipped with an ash breaker
that moves up and down in front of the burnpot. The
breaker has teeth on it that break any klinkers (lumps of
ash) and prevent any ash jamming. This allows the stove
to be much shorter front to back.