Some of the hydromassage nozzles are connected to one
another via one or more diverters (
use the diverter to adjust the flow of water to a set of noz-
zles, with respect to the other set, in indirect proportion. That
is, by turning the knob one way or the other, the force of the
jets will increase in one set of nozzles and decrease in the
other.
CAUTION
Do not use the diverter(s) when the pump is in
action.
I
"Light"
key
Press this key (the respective LED will come on) to turn
on the spotlight. Press it again to turn it off. The spotlight au-
tomatically switches off after it has been on for 2 hours of
operation.
I
Temperature control
The water is heated by a tubular electrical heater. Do not set
an excessively high water temperature, i.e. over the limit of 40
°C. The recommended temperature is 35-36 °C.
NOTE: If the electric consumption limiter is activated (se the
related chapter) should the pump be turned on at high speed,
the heater will be turned off (the symbol
display) and it is turned back on, if needed, 5 minutes after the
pump is turned off.
I
Temperature unit of measure
The temperature scale is set to °C. It can be changed to °F as fol-
lows:
Press and hold the "Light"
til the message "cFn" appears.
If necessary, use the "Up"
scroll the menu until you see the message "cFn". Press the
"Light"
key again to confirm the option.
Now insert the password 123 as follows:
- use the "Up"
and/or "Down"
number.
- confirm the selection by pressing the "Light"
Perform the same steps to insert the other two numbers.
Once you have inserted the password, the display will show
the message I1x (where "x" may be 1 or 0; the memorized val-
ue is 0).
i
8, detail B). You can
will flash on the
key for about 12 seconds, un-
and/or "Down"
keys to
keys to insert the first
key.
Use the keys "Up"
from 0 a 1 (corresponding to the scale in °F). Confirm the se-
lection with the "Light"
sage I2x. Press the "Light"
I3 0, which must never be modified.
Press the "Light"
and memorize the new values. The display will go off for a mo-
ment, and then it will come on again.
To go back to the Celsius scale (°C), return to the procedure and
set figure "x" of the parameter I1x to 0.
NOTE: If no key is pressed for 20 seconds, you will exit the
procedure and any changes made will not be saved.
I
Water heating temperature ("set point")
To check or modify the water heating temperature, do the follow-
ing:
Press the "Up"
the current memorized temperature (in °C or °F as pro-
grammed, see "Temperature unit of measure) and the respec-
tive symbol appears.
Press the "Up"
displayed value from a minimum of 15 °C to a maximum of 40
°C (59 ÷ 104 °F).
To show the temperature of the water in the tub again, do not
touch any key for about 5 seconds.
As soon as the water temperature set point is reached, the
heater is shut off. It will not be turned back on until the water
temperature drops about 0.5 °C - 1 °F below the set point.
To ensure precise measurement of the water temperature,
the filtering pump comes on every half hour for about 30 sec-
onds (even if no filtering cycles are set), since the temperature
probe is located in the heater pipe.
NOTES
- When the system is turned off, or there is a power outage,
the last set point is stored in memory.
- Operation of the heater is shown on the display by a symbol
displayed steady. If it is flashing, it means that heating has
been suspended to keep from exceeding the maximum per-
mitted consumption. See also the previous note.
CAUTION
Do not use the water at temperatures over
40°C.
29
and/or "Down"
key. The display will show the mes-
key again to go to parameter
key one more time to exit the procedure
or "Down"
key. The display will show
or "Down"
key again to change the
to change "x"