D. If pilot light does not light, turn control knob to 'OFF' position, wait five minutes and repeat steps A to C.
Note. If pilot flame is smaller than the parameters described in part A, check the pilot gas line (6mm stainless steel
flexible tube) for any possible blockages/crimp age. To gain a access to gas control components, remove control
knobs and undo screws located on either side and at the top of the front panel. Remove front panel (reassemble in
reverse order).
E. Once pilot is established turn control knob anti-clockwise to the 'HIGH' position. Examine flame.
F. Turn control knob clockwise the 'LOW' position. Examine flame.
G. Turn control knob clockwise the 'OFF' position.
H. Repeat steps A to H for all burners.
If pot burner is not fitted with pilot and/or flame failure
A. Ensure gas control in the 'OFF' position.
B. Depress operating knob of relevant burner and turn anti-clockwise 180
Examine flame.
C. Turn control knob clockwise to the 'HIGH' position. Examine flame.
D. Turn control knob clockwise to the 'OFF' position.
E. Repeat steps A to D for all burners.
Adjusting aeration of pot burner (if required)
ALWAYS CAUTION WHEN REMOVING TRIVETS AND BURNERS, SURFACE MAY BE HOT.
If necessary to adjust aeration to burners;
To adjust pot top burners, remove front burners by lifting the burner at the rear, and then slowly pulling it
towards the splash back (rear) of the appliance. Adjust the interrupter screw located at the top end of the
venture section as required (Clockwise: more interruption, Anti-Clockwise: less interruption). Replace burner
and light. Repeat the process if necessary for all burners.
CHIMNEY/DUCK BILL – WHERE FITTED
A. Light the appliance by pressing in the flame safe guard (blue) button and while holding it in turn the pilot
burner knob anti-clockwise to 'ON'. B. Light pilot manually.
C. Continue to hold in the flame sage guard button for about 25 to 30 seconds.
D. Observe whether the pilot is alight.
E. If not repeat steps A to D.
F. If it is alight turn main burner valve anti-clockwise to the 'ON' positions
G. Check that burner is properly alight.
In the event the appliance fails to operate correctly, check following;
1. Data plate to ensure correct gas type and pressure (adjust if necessary).
2. Adjust aeration by adjusting air shutter located at the front of the venture of the main burner.
3. Injector sizes – check against data plate and installation manual.
4. View pilot size and adjust if required.
In case appliance fails to operate correctly after all checks have been carried out, please contact;