INSTALLATION, OPERATING AND SERVICING INSTRUCTION MANUAL UFWSP & UFWWSP Series Commercial Stock Pot / Boiling Top Model No’s.: UFW–W–D–SP-1/2/3–CB-LS Approval No.; GMK10345 Manufactured By; B&S Commercial Kitchens Pty Ltd 57 Plateau Road Reservoir VIC 3073 AUSTRALIA Tel: +61 3 9469 4754 Fax: +61 3 94694504 Web: www.bscommercialkitchens.com Please ensure this booklet is kept in a safe and prominent location for future reference.
Table of Contents INSTALLATION, OPERATING AND SERVICING INSTRUCTION MANUAL ....1 UFWSP & UFWWSP Series Commercial Stock Pot / Boiling Top ........1 Product Specifications & Introduction ................4 IMPORTANT WARNINGS....................5 Table 1: Nominal Terminal Input Rates & Injector Sizes ................5 Table 2: Standard Model General Information ....................
Page 3
Maintenance and Care ......................10 Servicing Instructions ..................... 11 Abnormal Operation ......................11 Gaining Access to Gas and/or Water System ............... 11 Removal of Burner for Service ....................11 Pilot and Flame Safeguard ....................11 Adjustments ........................... 12 Servicing WokSpout – Where Fitted..................12 Servicing Knee Valve –...
Product Specifications & Introduction Appliance Name: UFSP & UFSPW Series Commercial Stock Pot Table This appliance may be branded as B&S, Kirana and Verro Manufactured By: B&S Commercial Kitchen s Pty Ltd Certificate Holder: 57 Plateau Road Reservoir Victoria 3073 Tel;...
IMPORTANT WARNINGS THIS APPLIANCE SHALL ONLY BE INSTALLED/SERVICED BY AN AUTHORISED INSTALLER. THIS APPLIANCE MUST BE INSTALLED IN ACCORDANCE WITH THE SPECIFIED INSTRUCTIONS AND SPECIFICATIONS. IMPROPER INSTALLATION OPERATION THIS APPLIANCE MAY RESULT IN PRODUCT FAILURE WHICH MAY LEAD TO PROPERTY DAMAGE, PERSONAL INJURY OR DEATH.
Figure 1: Plumbing Connections Table 3: Plumbing Connections Connection Position from Position from Position from Floor Rear of Appliance LHS/RHS edge (mm) (mm) of Appliance (mm) ½” Copper 310 (+/-5) 60 (+/-5) 220 (+/-5) Water Inlet (WI) Gas Inlet (GI) ¾”...
Leave a clearance of at least 200mm between the appliance and any combustible surface. No combustible materials shall be located within 500mm of the stock pot table. Gas Connection The gas connection is male 3/4” BSP and is situated at the rear of the appliance below the main body frame.
Chimney Burners – Pilot Light Chimney Burner A. Ensure pilot light head is located no further than 45mm from the injector located opposite the burner inlet. In the event the appliance fails to operate correctly, check the following; 1. Data plate to ensure correct gas type and pressure (adjust if necessary) 2.
Shutdown Procedure 1. Turn main gas valve to ‘OFF’. 2. Turn pilot control valve clockwise to turn off. 3. Observe pilot flame is extinguished. Deck Cooking (Water Spray) – Where Fitted (Water Cooled Models) Deck cooling must be activated whenever the main stock pot burners are in use to prevent the deck of the appliance from buckling and distorting.
IMPORTANT WARNING! IN THE EVENT OF FAILURE OF THE WOKSPOUT, WATER FLOW CAN BE CONTROLLED MANUALLY BY USING THE SPINDLE LOCATED ON FRONT PANEL (WHERE FITTED). WHERE NO SPINDLE FITTED, WATER SHOULD BE SWITCHED OFF FROM THE ISOLATION VALVE (WHICH IS RECOMMENDED TO BE FITTED WHEN ISTALLED) AND CONTACT AUTHORISED/ LICENSED SERVICE PERSONNEL.
Servicing Instructions WARNING! Servicing shall be carried out by autorised personnel only. Failure to do so will void the B&S warranty and may result in damage to equipment or injury to personnel. Before commencing any disassembly/ assembly of gas controls, please ensure the gas supply is turned off (isolated).
c. Remove injector from pilot and clean (if required). d. Reassemble in reverse order. 3. REASSEMBLE IN REVERSE ORDER. Adjustments Pilot 1. Remove front panel as described under GAINING ACCESS TO GAS CONTROL. 2. To increase gas pressure to pilot, turn adjustment screw located at the top right hand side of the flame failure devise anti-clockwise.
Table 4: Spare Parts List Part Number Description 001NG Chimney Burner (Natural Gas) Chimney Burner (LP/Propane Gas) 001LP ¾” M&F Ball Valve Red Handle for Ball Valve 005A ¾” D3 Safety Valve (Blue Button) Pilot Gas Cock Pilot Gas Cock Knob 011NG Round Pilot (Natural Gas) 011LP...
Table 5: Troubleshooting FAULT POSSIBLE CAUSE CHECKS Blockage of pilot Check pilot injector is not blocked as described in servicing instructions - pilot and flame safeguard Pilot light not igniting Adjustment of pressure from flame Check gas pressure to pilot as control described under servicing instruction - adjustments...