Diverter Valve Lubrication

33. Lubricate the diverter valve. Remove the right-hand side panel. Using a spray can of PTFE lubricant* with a precision spray
straw attached, spray a small amount of lubricant directly onto the drive shaft of the diverter valve. Wipe away any excess lubricant.
Failure to lubricate the diverter will result in premature failure and may void the warranty of this item. Reinstall the side panel upon
completion.
Warning
Read and follow all safety precautions on the label of lubricant
Drive Shaft (Brass)
Space Between Motor and Valve Assembly
*'Superlube' is an example