Dräger INTERLOCK 7 Series User Manual

Dräger INTERLOCK 7 Series User Manual

Qld performance-based alcohol interlock program

Advertisement

Quick Links

DRÄGER INTERLOCK
7XXX
®
User Guide
QLD Performance-Based Alcohol Interlock Program

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the INTERLOCK 7 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Dräger INTERLOCK 7 Series

  • Page 1 DRÄGER INTERLOCK 7XXX ® User Guide QLD Performance-Based Alcohol Interlock Program...
  • Page 2 What is the Dräger Interlock 7XXX? ® The Dräger Interlock® 7XXX is a reliable and precise alcohol measuring instrument with an integrated vehicle immobiliser. It prevents a person who consumes alcohol from starting the vehicle. The Dräger Interlock® 7XXX consists of two components: handset and control box. If required, the device can be additionally equipped with a camera and/or a remote download module.
  • Page 3 Important to know - Keep the unit clean and dry at all times. - Use a clean and dry mouthpiece when providing breath samples. - Do not eat, consume alcohol, use alcohol-based products, including mouthwash or smoke for 15 minutes before using the Dräger Interlock®...
  • Page 4 How do I start the Vehicle? 1. Wait 15 minutes after eating, drinking, smoking or using alcohol-based products. It is also recommended to rinse the mouth with water before providing a breath test. 2. Ensure a clean mouthpiece is inserted properly into the Dräger Interlock®...
  • Page 5 How do I know if I am blowing and sucking correctly? The Dräger Interlock® 7XXX will let you know if you are not presenting a correct sample. If an error occurs during the breath test, the device will alert you with audible and visual signals.
  • Page 6 Violation reset Excessive violations will cause the Dräger Interlock® 7XXX to require a service earlier than scheduled and may result in program extensions. To avoid Violation Resets, it is important that you adhere to the program rules. A “VIOLATION RESET” can be caused by: –...
  • Page 7 Service requirements Your scheduled services will be set to the day of installation, called the anniversary date. For example, if the Dräger Interlock® 7XXX is installed on the 23rd of January, the next service date will be set to the 23rd of February. At each service, your next anniversary date will be programmed into the Dräger Interlock®...
  • Page 8 For service appointments or emergencies, please contact your local Dräger authorised Service Agent on: Draeger Australia Pty. Ltd. 8 Acacia Place Notting Hill VIC 3168 Phone: 1300 780 689 interlock.australia@draeger.com DSP SE6010 A286 Rev.1...