9.5.2

Converting heating elements

W5130H can be converted from 380-415V 3N AC to 220-240V 1N AC with reduced power
Disconnect the power to the machine.
Demount the cover panel to the electrical connections.
Remove the cables that are connected to K21:2 and K22:6. Move the remaining cables from L2 and L3 to L1 or N ac-
cording to the figure.
380-415V 3N
Q1
T1
L1
301
L1
T2
L2
L2
T3
L3
L3
302
N1
N
N
PE
6
4
5
3
~400V
E1
E2 E3
Remount the cover panel to the electrical connections.
Connect the power to the machine.
Check that all terminals and wires are secure and test run the machine on a short program with 60°C to ensure that it
does heat up.

10 Steam connection

Inlet pipes connected to the machine must be equipped with a manual shut-off valve to facilitate installation and serv-
icing. The connection hose must be of type ISO/1307- 1983 or equivalent.
Connection size at filter: DN 15 (BSP 1/2").
Demount the top panel (A). Demount the casing (B).
Installation manual
2
6
4
2
K21
K22
1
5
3
1
B
220-240V 1N
with reduced heating power
Q1
T1
L1
301
L1
From L3
T2
L2
L2
From L2
T3
L3
L3
302
N1
N
N
PE
Remove
6
4
2
K21
5
3
1
~230V
E1
E2 E3
A
37
6
4
2
K22
5
3
1
fig.W00620