How To Convert Heating Elements From 3Ac To 1Ac - Electrolux W465H Installation Manual

Hide thumbs Also See for W465H:
Table of Contents

Advertisement

48
How to convert heating elements from 3AC to 1 AC with reduced effect
(400-415V 3AC to 230-240V 1AC) on W465H, W475H and W4105H.
• Take off isolator cover plate and front panel to expose heating elements.
• Remove the cables A.
46
46
E1
E1
• Take off wire (B) from terminal L2 on isolator Q1 and reconnect it to
47
terminal N (neutral) instead.
• The heating elements have coloured insulators on the tips, ine is red,
the other is white.
Connect cable 356 from heating relay K21 connection 1 on the white
connection on E1. Connect cable 358 from heating relay K21 connec-
tion 3 on the white connection on E3.
• Check that all your terminals and wires are secure, then test the machi-
ne on a short wash 60°C to ensure that it does heat up.
• Fasten isolator cover front panel to the machine.
Note!
The wires from terminal 5 on contactor K21 to the redundant heating ele-
ment can be safely left on.
47
Installation
400­415V 3AC
E2
A
230­240V 1AC
E2
B
E3
5835
E3
6655
W00010