Features and Specifications
Specifications
Table 1.6 Specifications for XHR 1000 W Series Supply with GPIB Interface Installed (100 V to 600 V)
Models
Program Resolution
Voltage
Current
OVP
Program Accuracy
Voltage
Current
OVP
Readback Resolution
Voltage
Current
Readback Accuracy
Voltage
Current
1. Apply accuracy specifications according to the following voltage program accuracy example:
Set a model 20-50 power supply to 10 volts.
The expected result will be within the range of 10 volts ± 50mV ± 0.12% of the set voltage of 10 volts.
14
100-10
15.4mV
3.92mA
15.4mV
1
150mV
±0.35%
140mA
±0.15%
800mV
15.4mV
3.92mA
1
150mV
±0.35%
140mA
±0.15%
150-7
300-3.5
23.1mV
46.2mV
2.52mA
1.26mA
23.1mV
46.2mV
225mV
225mV
±0.35%
±0.35%
120mA
80mA
±0.1%
±0.1%
1.5V
3.0V
23.1mV
46.2mV
2.52mA
1.26mA
225mV
225mV
±0.35%
±0.35%
120mA
80mA
±0.1%
±0.1%
Operating Manual for GPIB for XHR/XFR Series Power Supply
600-1.7
92.4mV
0.56mA
92.4mV
250mV
±0.35%
80mA
±0.1%
6V
92.4mV
0.56mA
250mV
±0.35%
80mA
±0.1%