Specifications - Ametek Sorensen GPIB-XHR Operation Manual

Internal gpib interface for xhr/xfr series, programmable dc power supplies
Table of Contents

Advertisement

Specifications

The specifications in this section are warranted at 25°C ±5°C unless otherwise
specified. All specifications are subject to change without notice.
Table 1.1 Specifications for XFR 1200 W Series Supply with GPIB Interface Installed (7.5 V to 40 V)
Models
Program Resolution
Voltage
Current
OVP
1
Program Accuracy
Voltage
Current
OVP
Readback Resolution
Voltage
Current
1
Readback Accuracy
Voltage
Current
1. Apply accuracy specifications according to the following voltage program accuracy example:
Set a model 20-60 power supply to 10 volts.
The expected result will be within the range of 10 volts ± 75mV ± 0.12% of the set voltage of 10 volts.
7.5-140
12-100
1.16mV
1.8mV
19.6mA
14mA
1.16mV
1.8mV
10mV
50mV
±0.12%
±0.12%
500mA
460mA
±0.1%
±0.1%
80mV
150mV
1.16mV
1.8mV
19.6mA
14mA
30mV
60mV
±0.12%
±0.12%
500mA
460mA
±0.1%
±0.1%
Features and Specifications
20-60
35-35
3.08mV
5.4mV
8.4mA
5.4mA
3.08mV
5.4mV
75mV
75mV
±0.12%
±0.3%
250mA
200mA
±0.1%
±0.1%
200mV
350mV
3.08mV
5.4mV
8.4mA
5.4mA
75mV
75mV
±0.12%
±0.3%
250mA
200mA
±0.1%
±0.1%
Specifications
40-30
6.2mV
4.2mA
6.2mV
75mV
±0.3%
150mA
±0.15%
400mV
6.2mV
4.2mA
75mV
±0.3%
150mA
±0.15%
9