Features and Specifications
Specifications
Table 1.2 Specifications for XFR 1200 W Series Supply with GPIB Interface Installed (60 V to 600 V)
Models
Program Resolution
Voltage
Current
OVP
1
Program Accuracy
Voltage
Current
OVP
Readback Resolution
Voltage
Current
1
Readback Accuracy
Voltage
Current
1. Apply accuracy specifications according to the following voltage program accuracy example:
Set a model 20-60 power supply to 10 volts.
The expected result will be within the range of 10 volts ± 75mV ± 0.12% of the set voltage of 10 volts.
10
60-20
100-12
9.2mV
15.4mV
2.8mA
1.68mA
9.2mV
15.4mV
150mV
150mV
±0.25%
±0.35%
120mA
80mA
±0.1%
±0.1%
600mV
800mV
9.2mV
15.4mV
2.8mA
1.68mA
150mV
150mV
±0.25%
±0.35%
120mA
80mA
±0.1%
±0.1%
150-8
300-4
23.1mV
46.2mV
1.12mA
0.56mA
23.1mV
46.2mV
225mV
225mV
±0.35%
±0.35%
80mA
80mA
±0.1%
±0.1%
1.5V
3.0V
23.1mV
46.2mV
1.12mA
0.56mA
225mV
225mV
±0.35%
±0.35%
80mA
80mA
±0.1%
±0.1%
Operating Manual for GPIB for XHR/XFR Series Power Supply
600-2
92.4mV
0.28mA
92.4mV
250mV
±0.35%
50mA
±0.1%
6V
92.4mV
0.28mA
250mV
±0.35%
50mA
±0.1%