Heater (1) with suspension bracket (9), electrical cable and plug
Wall bracket (2) (2x) with wing nut (3) for fastening. Use a wing nut for
securing the bracket.
Three brackets (4) (various sizes) for suspension to tent frame, parasol or
similar item, with two wing nuts (3).
The remote control (8)
and fastening material.
The Eurom Golden 2000 Amber Focus has a separated electrical part with the
receiving point for the remote control and a display. The reset button (6) and the
On/Off switch (5) are located at the rear.
The Eurom Golden 2000 Amber Focus is equipped with a top quality 2000W Golden
Amber ULG lamp that produces 90% less light.
Alongside the comfortable 2000W heat, the Golden ULG lamp also emits a natural,
warm, subtle glow. The lamp has an expected life of 8,000 hours; under normal
circumstances, it should not have to be replaced.
Very intensive use can lead to precocious aging of the lamp and of course an
accident can break it. In that case, contact your dealer or a qualified electrician.
The lamp has a special connection and it is not allowed to not-qualified people to
remove or change it.

Installation

The Eurom Golden 2000 Amber Focus can be installed in 2 ways:
 Suspension from a wall (or possibly ceiling) by means of a wall bracket
 Suspension from a frame (parasol, tent or similar item) by means of a bracket
Remove all package material (including the shock absorbing material around the
bulb) before installating the heater and check the appliance, supply cord and the
plug for signs of damage.
Carefully choose the right place to install your heater.
Before fastening, check that the minimum safe distances between the surroundings
and the chosen location are respected:
Minimum distance lowest point of heater – floor: 1,8 metres
Minimum distance heater – heated object: 1 metre
Minimum distance top* heater – fire-resistant ceiling: 0.25 metres
Minimum distance top* heater – tent tarpaulin, parasol etc.: 0.5 metres
Minimum distance side heater – walls, obstacles, objects: 0.5 metres
* The top of the heater is the side where the suspension bracket is attached.
If you suspend the device outside, ensure that it is protected from the wind.