Parameter
Tilt Reverse
Pan Degree
Encoders
Pan/Tilt Spd
Hibernation
Defogger
Dimming Mode
Out Rig Mode
P/T Home Mode
Prism/Frost Sel
Configure the Fixture
Value
Description
ON
Reverse the tilt movement of the fixture. The default value is
•
OFF
OFF.
•
630
Change the pan rotation of the fixture from the default
•
setting of 540 degrees to 630 degrees.
540
•
Turn on or off the encoder feedback for pan and tilt
ON
movement. You may want to turn off encoders when
•
working on a fixture so that you can move pan and tilt
OFF
•
without the fixture automatically moving back to position.
Set the speed (scan mode) of pan and tilt movement. The
default value is 1. Use this parameter to make fine
1–4
adjustments to pan and tilt movement in order to correct for
mis-stepping when the fixture is installed on its side (side-
hung, or "Outrig").
Hibernation mode forces the LEDs and stepper motors to
OFF
•
power off when the fixture loses DMX control signal for a set
1–99 minutes
•
period of time. The default time setting is 15 minutes.
Set when the Defogger (heater for the front lens) is turned
on:
Defog OnOP
•
•
Defog OnPwr
•
Defog Off
•
•
•
Set the dimming curve and pulse width modulation (PWM)
Standard
frequency. The PWM frequency is 16 kHz in Standard mode
•
and 2.4 kHz in Theatrical mode. The default value is
Theatrical
•
Standard.
Turn on when the fixture is installed on its side (side hung, or
ON
•
"Outrig"). This parameter reduces the speed of pan and tilt
OFF
•
movement to correct for mis-stepping.
Set the order in which pan and tilt homing is performed.
•
Standard
•
Tilt First
•
•
Pan First
•
•
Prism Mode
If you have installed a frost in the prism slot, select Dual
•
Frost Mode so that the fixture will home appropriately. The
Dual Frost
•
default setting is Prism Mode.
Mode
Defog OnOP: Turn on Defogger when LEDs are above
0% intensity
Defog OnPwr: Turn on Defogger when the fixture is
powered (default value)
Defog Off: Turn off Defogger
Standard: the pan and tilt home procedures run
simultaneously.
Tilt First: the tilt home procedure runs to completion,
then the pan home procedure begins.
Pan First: the pan home procedure runs to completion,
then the tilt home procedure begins.
19