ID ISC.LRM2500-B
Long Range Reader
(English)
final – public (B)
2016-02-17 – M01111-4e-ID-B.docx

Advertisement

Table of Contents
loading

Summary of Contents for Feig Electronic OBID i-scan ID ISC.LRM2500-B

  • Page 1 INSTALLATION ID ISC.LRM2500-B Long Range Reader (English) final – public (B) 2016-02-17 – M01111-4e-ID-B.docx...
  • Page 2 FEIG ELECTRONIC GmbH assumes no responsibility for the use of any information contained in this docu- ment and makes no representation that they free of patent infringement. FEIG ELECTRONIC GmbH does not convey any license under its patent rights nor the rights of others.
  • Page 3: Table Of Contents

    Data-Clock Interface on connector X2 ..............25 Operating and Display Elements LEDs .......................... 27 Button T1 ........................28 Radio Approvals Europe (CE) ....................... 29 USA (FCC) and Canada (IC) ..................30 Technical Data FEIG ELECTRONIC GmbH Page 3 of 32 M01111-4e-ID-B.docx...
  • Page 4: Safety Instructions / Warning - Read Before Start-Up

    Although this device doesn't exceed the valid limits for electromagnetic fields you should keep a minimum distance of 25 cm between the device and your cardiac pacemaker and not stay in the immediate proximity of the device’s antenna for any length of time. FEIG ELECTRONIC GmbH Page 4 of 32 M01111-4e-ID-B.docx...
  • Page 5: Performance Features Of Reader Family Id Isc.lrm2500

    Host und Embedded Linux ID ISC.LR2500-A Housing version with RS232/485- / USB- / LAN-Interface, USB- Host und Embedded Linux ID ISC.LRM2500-B Module version with RS232/485- / USB- / LAN-Interface Table 1: Available Reader types FEIG ELECTRONIC GmbH Page 5 of 32 M01111-4e-ID-B.docx...
  • Page 6: Installation And Mounting

     4.5 mm holes located in each corner of the base plate (see: Figure 1). 16,3 ø 4,5 mm ø 4,5 mm ø 4,5 mm* ø 4,5 mm* ø 4,5 mm* Figure 1: Scale drawing of the Reader module with mounting plate FEIG ELECTRONIC GmbH Page 6 of 32 M01111-4e-ID-B.docx...
  • Page 7 Reader. In such cases the Reader regulates its output power down until the upper temperature limit of its final stage fallen down again. FEIG ELECTRONIC GmbH Page 7 of 32 M01111-4e-ID-B.docx...
  • Page 8: Terminals

    ® OBID i-scan Installation ID ISC.LRM2500-B 3.2 Terminals Figure 2 shows the terminals and control elements of the ID ISC.LRM2500-B Figure 2: Reader terminals FEIG ELECTRONIC GmbH Page 8 of 32 M01111-4e-ID-B.docx...
  • Page 9: Antenna Connection

     When connecting an antenna, ensure that it does not exceed the permissible limits pre- scribed by the national regulations for radio frequency devices. Figure 3: Antenna line with EMC ring cores FEIG ELECTRONIC GmbH Page 9 of 32 M01111-4e-ID-B.docx...
  • Page 10: Supply Voltage

    EMC ring cores  28 mm x 20 mm. The power supply line must be wound around the ring core for at least 5 turns. The distance between the Reader termination and the ring core should be maximum 10 cm. FEIG ELECTRONIC GmbH Page 10 of 32 M01111-4e-ID-B.docx...
  • Page 11: Fuse F1

    Figure 5: Position of the fuse F1 Attention!:  The 24V voltage for supplying the internal and external DC voltage on X2 for the dig- ital inputs and outputs is not protected by the fuse F1. FEIG ELECTRONIC GmbH Page 11 of 32 M01111-4e-ID-B.docx...
  • Page 12: X2: Optocoupler Inputs (X2 / In1, In2, In3)

    All 3 inputs are identical and may therefore be configured individually. 24 V   Uext 24 V   Uext 24 V   Uext Figure 7: External power supply for the optocouplers on X2 FEIG ELECTRONIC GmbH Page 12 of 32 M01111-4e-ID-B.docx...
  • Page 13 20mA. For voltages of less than 10V a part of the series resistance must be jumpered (J1, J3, J5) accordingly. Figure 9: Position of the Jumper J1- J9 FEIG ELECTRONIC GmbH Page 13 of 32 M01111-4e-ID-B.docx...
  • Page 14 The internal 24V voltage for supplying the DC voltage on the digital inputs is not protected by the fuse F1.  Using internal and external voltage at the same time can destroy the reader. FEIG ELECTRONIC GmbH Page 14 of 32 M01111-4e-ID-B.docx...
  • Page 15: Optocoupler Outputs (X2 / Out1, Out2)

    The output is configured for max. 24 V / 30 mA.  Polarity reversal or overload on the output will destroy it.  The output is intended for switching resistive loads only. FEIG ELECTRONIC GmbH Page 15 of 32 M01111-4e-ID-B.docx...
  • Page 16: Relay (X2 / Rel1, Rel2, Rel3)

    Figure 12: Relay Outputs on terminal X2 24 V REL3 Uext 24 V REL2 Uext 24 V REL1 Uext Figure 13: Internal and possible external wiring of the relay output’s with external voltage FEIG ELECTRONIC GmbH Page 16 of 32 M01111-4e-ID-B.docx...
  • Page 17  The internal 24V voltage for supplying the DC voltage on the relays is not protected by the fuse F1.  Using internal and external voltage at the same time can destroy the reader. FEIG ELECTRONIC GmbH Page 17 of 32 M01111-4e-ID-B.docx...
  • Page 18: (X2 / 24V, Gnd)

     For the dimensioning of the power supply the power consumption for the external output circuitry must be additional considered to the typical reader power consumption.  The internal 24V voltage on X2 is not protected by the fuse F1. FEIG ELECTRONIC GmbH Page 18 of 32 M01111-4e-ID-B.docx...
  • Page 19: X8: External Diagnostic Led Connections

     If only one output is used the maximum current consumption is I =15mA. The total current consumption of all 5 outputs together should not increase 25mA. The off-load output voltage is 3,3V and is supplied via a 220Ohm series resistor. FEIG ELECTRONIC GmbH Page 19 of 32 M01111-4e-ID-B.docx...
  • Page 20: Interfaces

    Figure 17: RS232 interface pin-outs on X3 Kurzzeichen Description RS232 – (Transmit) RS232 – (Receive) RS232 – (Ground) Table 10: Pin assignment of the RS232-Interface Figure 18: Wiring example for connecting the RS232 interface FEIG ELECTRONIC GmbH Page 20 of 32 M01111-4e-ID-B.docx...
  • Page 21: Rs485-Interface X3

    Pull-Down on RS4xx - A Pull-Up on RS4xx - B without Pull-Up on RS4xx - B Table 12: Jumper of the RS485-interface Note: The Termination can be activated via software in the reader configuration. FEIG ELECTRONIC GmbH Page 21 of 32 M01111-4e-ID-B.docx...
  • Page 22 The termination of the RS485 Bus can be configured via software. See system manual. Note: Since all Readers are factory set with address „0“, they must be connected and configured one after the other. FEIG ELECTRONIC GmbH Page 22 of 32 M01111-4e-ID-B.docx...
  • Page 23: Usb - Interface X4 (Host Communication, Hid)

    12 Mbit (USB full speed). A standard USB-cable can be used. Figure 22: USB-Interface for host communication Note: The length of the USB-cable can be a max. of 5m (20 inch). It is not allowed to use longer cables. FEIG ELECTRONIC GmbH Page 23 of 32 M01111-4e-ID-B.docx...
  • Page 24: Ethernet-Interface On X1 (10/100 Base-T)

    Table 13 Standard factory configuration of the Ethernet connection Note:  The Reader TCP/IP interface has a DHCP option.  It is recommended to use a shielded twisted pair STP CAT5 cable. FEIG ELECTRONIC GmbH Page 24 of 32 M01111-4e-ID-B.docx...
  • Page 25: Data-Clock Interface On Connector X2

    The digital outputs OUT1 and OUT2 are not available, if the data-clock interface is activated. The data as well as the clock need to be supplied with an external voltage. The output is configured for max. 24 V DC / 30 mA. FEIG ELECTRONIC GmbH Page 25 of 32 M01111-4e-ID-B.docx...
  • Page 26 The necessity of the external pull down resistor is depending on the inner circuit of the used Wiegand Controller The total resistance incl. the input resistance of the Wiegand Controller should be ± 1kOhm 10% . FEIG ELECTRONIC GmbH Page 26 of 32 M01111-4e-ID-B.docx...
  • Page 27: Operating And Display Elements

    Comes on when there is an error in the RF section of the Reader. The error type can be read out via software over the RS232 / RS485 / USB and LAN-Interface Table 14: LED configuration FEIG ELECTRONIC GmbH Page 27 of 32 M01111-4e-ID-B.docx...
  • Page 28: Button T1

    ® OBID i-scan Installation ID ISC.LRM2500-B 4.2 Button T1 Abbreviation Description Reader reset button Table 15: Reset Button Pressing T1 resets the reader controller FEIG ELECTRONIC GmbH Page 28 of 32 M01111-4e-ID-B.docx...
  • Page 29: Radio Approvals

    When used according to regulation, this radio equipment conforms with the basic requirements of Article 3 and the other relevant provisions of the R&TTE Guideline 1999/E6 dated March 99. Equipment Classification according ETSI EN 300 440 and ETSI EN 301 489: Class 2 FEIG ELECTRONIC GmbH Page 29 of 32 M01111-4e-ID-B.docx...
  • Page 30: Usa (Fcc) And Canada (Ic)

    Warning: Changes or modification made to this equipment not expressly approved by FEIG ELECTRONIC GmbH may void the FCC authorization to operate this equipment. Installation with FCC / IC Approval: FCC-/IC-NOTICE: To comply with FCC Part 15 Rules in the United States / with IC Radio Stand- ards in Canada, the system must be professionally installed to ensure compliance with the Part 15 certification / IC certification.
  • Page 31: Technical Data

    / 1 A  Inputs – 3 Optocoupler 5- 24 V / 20 mA (See chapter: 3.6)  RS232  Interfaces  RS485  USB – Interface (HID)  Ethernet (TCP/IP)  Data Clock FEIG ELECTRONIC GmbH Page 31 of 32 M01111-4e-ID-B.docx...