2-2.

Audio System

2-2-1.

Intercom System Setting

Two independent intercom lines (producer line and engineer line) are selectable and available in this unit.
This unit supports 4-wire, RTS, and Clear-Com intercom systems. Make settings of the internal switches and menus
according to the system to be used.
Selecting Intercom System
Set the intercom system with SYSTEM I/F of the CCU CONFIGURATION menu (C06).
Select an intercom system (CLEAR COM, 4 WIRE, or RTS ) according to the system to be used.
Note
When intercom system is set to RTS or CLEAR COM be sure to connect the unit to the RTS or Clear-Com system.
Failure to do so will cause the output to oscillate and adversely affect the surrounding circuit.
Adjusting RTS Cancellation (RTS/Clear-Com)
Note
For HSCU300R, remove the DM-152 board and make adjustment.
When the RTS or Clear-Com system is used, adjust the sidetone cancellation amount using the following procedure.
Before beginning adjustment it is recommended to make a copy of setup conditions. You can easily restore the original
settings after adjustment.
1.
Set the SIDE TONE value of the CCU CONFIGURATION menu (C07) to 0.
2.
Set the INTERCOM switch on the front panel to PROD.
3.
While speaking to the headset microphone, adjust potentiometer RV1050 (PROD RTS/CC CANCEL) on the
DPR-361 board so that the voice heard from the headset becomes minimum.
4.
Set the INTERCOM switch on the front panel to ENG.
5.
While speaking to the headset microphone, adjust potentiometer RV1051 (ENG RTS CANCEL) on the DPR-361
board so that the voice heard from the headset becomes minimum.
6.
Re-set the SIDE TONE value of the CCU CONFIGURATION menu (C07) to the customer settings.
A
B
C
DPR-361 board (Side A)
Setting PGM Audio Signal Input Level
Set the PGM audio signals (PGM1 and PGM2) with PGM1 INPUT and PGM2 INPUT of the CCU CONFIGURATION
menu (C06) according to each signal level.
-20, 0, +4 dBu (factory setting: 0 dBu)
HSCU300RF/HSCU300R
D
E
F
G
1
2
3
4
5
6
RV1050
RV1051
7
8
2-2