Fujitsu AUXG36KRLB Service Manual page 57

Cassette type
Hide thumbs Also See for AUXG36KRLB:
Table of Contents

Advertisement

Check point 4. Check serial signal (Forward transfer signal)
Check serial signal (Forward transfer signal)
Check if indicated value swings between AC 30 V and AC 130 V at outdoor unit terminal 2—3.
If it is abnormal, replace main PCB.
Check point 1-2. Check external cause such as noise
Check the complete insulation of the grounding.
Check if there is any equipment that causes harmonic wave near the power cable (Neon light
bulb or any electronic equipment which causes harmonic wave).
2-2. E: 11. Serial communication error (Serial forward transfer error) (Indoor unit)
BLACK
1
WHITE
2
3
RED
BLACK
L
WHITE
N
End
End
+
-
- (03-7) -
2. Troubleshooting with error code

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Auxg45krlbAuxg54krlbAoyg36kqtaAoyg45kqtaAoyg54kqta

Table of Contents