¢ Heat exchanger temperature thermistor
Temperature (°C)
-30.0
-25.0
-20.0
-15.0
-10.0
-5.0
0.0
5.0
10.0
15.0
20.0
25.0
30.0
35.0
40.0
45.0
50.0
55.0
60.0
65.0
70.0
75.0
80.0
¢ Outdoor temperature thermistor
Temperature (°C)
-30.0
-25.0
-20.0
-15.0
-10.0
-5.0
0.0
5.0
10.0
15.0
20.0
25.0
30.0
35.0
40.0
45.0
50.0
55.0
5-2. Outdoor unit
Resistance (kΩ)
95.58
68.90
50.31
37.19
27.81
21.02
16.05
12.38
9.63
7.56
5.98
4.77
3.84
3.11
2.53
2.08
1.71
1.42
1.19
1.00
0.84
0.71
0.61
Resistance (kΩ)
224.33
159.71
115.24
84.21
62.28
46.58
35.21
26.88
20.72
16.12
12.64
10.00
7.97
6.40
5.18
4.21
3.45
2.85
- (03-65) -
Voltage (V)
0.24
0.32
0.43
0.57
0.73
0.92
1.14
1.39
1.65
1.93
2.21
2.49
2.77
3.02
3.26
3.48
3.68
3.85
4.00
4.13
4.25
4.35
4.43
Voltage (V)
0.73
0.97
1.25
1.56
1.90
2.26
2.61
2.94
3.25
3.52
3.76
3.97
4.14
4.28
4.41
4.51
4.59
4.65
5. Thermistor resistance values