Immergas MAGIS COMBO PLUS V2 Series Instructions And Recommendations For The Installer page 57

Hide thumbs Also See for MAGIS COMBO PLUS V2 Series:
Table of Contents

Advertisement

Error Code
A469
Voltage sensor error of DC circuit (inverter)
A470
EEPROM reading/writing error of outdoor unit
A471
EEPROM reading/writing error of outdoor unit
A474
Inverter temperature sensor error
A475
Error of outdoor unit fan no.2 (where present)
A484
PFC overload
A485
Incoming current sensor error
A500
IPM overheated
A554
Gas leak error
A590
Inverter board error
A601
Not present
A604
Not present
A653
Not present
A654
Not present
A899
Not present
A900
Not present
A901
Not used
A902
Not used
A903
Not used
A904
Not used
(1) If the shutdown or fault persists, contact an authorised company (e.g. Authorised After-Sales Technical Assistance Centre)
Anomaly signalled
Indoor unit status / Solution / Solution
Check the power connector of the inverter board.
Check the connectors RY21 and R200 of the inverter board.
(1)
Check the main board.
(1)
Check the main board.
(1)
Replace inverter board (1)
Check the wiring.
Check that the fan is powered.
Check the board fuses.
(1)
Check inductances.
Replace inverter board.
(1)
Replace inverter board.
(1)
Check temperature of inverter board. Switch the machine off. Wait
for the inverter to cool down. Switch the machine back on.
(1)
Check that the coolant is charged
Check the liquid sensor of the indoor unit
Check whether the service valve is open
Check whether the installation pipes are mounted properly.
(1)
Check normal operation of the main board.
Replace the main board
(1)
(1)
(1)
(1)
(1)
(1)
(1)
Indoor unit error
Check indoor unit
(1)
Indoor unit error
Check indoor unit
(1)
Indoor unit error
Check indoor unit
(1)
Indoor unit error
Check indoor unit
(1)