Use In Fluids Hazardous To Health; Transport; Installing/Dismantling; During Operation - Wilo Rexa CUT GI Installation And Operating Instructions Manual

Hide thumbs Also See for Rexa CUT GI:
Table of Contents

Advertisement

differential triggering and anti-reactivation device in accordance
with the local regulations. In case of sensitive mains, make provi-
sion for the installation on-site of other protective equipment
(e.g. overvoltage, undervoltage or phase failure relay, etc.).
Residual-current device (RCD)
Comply with the regulations of the local energy supply company!
The use of a residual-current device is recommended.
If persons come into contact with the device and conductive flu-
ids, secure the connection with a residual-current device (RCD).
2.5

Use in fluids hazardous to health

There is a danger of bacterial infection when using the device in
fluids hazardous to health! Thoroughly clean and disinfect the
device after dismantling and prior to further use. The operator
must ensure the following:
ƒ
The following protective equipment is provided and worn when
cleaning the device:
Closed safety goggles
Breathing mask
Protective gloves
ƒ
All persons are informed about the fluid, the associated danger
and its correct handling!
2.6

Transport

ƒ
The following protective equipment must be worn:
Safety shoes
Safety helmet (when using lifting equipment)
ƒ
Always hold the handle to transport the device. Never pull the
power supply cable!
ƒ
Only use legally specified and approved lifting gear.
ƒ
Select the lifting gear based on the existing conditions
(weather, attachment point, load, etc.).
ƒ
Always attach the lifting gear to the attachment points (handle
or lifting eyelet).
ƒ
The stability of the lifting equipment must be ensured during
operation.
ƒ
When using lifting equipment, a second person must be
present to coordinate the procedure if required (e.g. if the op-
erator's field of vision is blocked).
ƒ
Persons are not permitted to stand beneath suspended loads.
Do not carry suspended loads over workplaces where people
are present.
2.7

Installing/dismantling

ƒ
Wear the following protective equipment:
Safety shoes
Safety gloves for protection against cuts
Safety helmet (when using lifting equipment)
Installation and operating instructions Wilo-Rexa CUT GI
Safety
ƒ
Locally applicable laws and regulations for work safety and ac-
cident prevention must be complied with.
ƒ
Disconnect the device from the mains and secure it against be-
ing switched on again without authorisation.
ƒ
All rotating parts must be at a standstill.
ƒ
Provide adequate aeration in closed rooms.
ƒ
When working in chambers and closed spaces, a second person
must be present for safety reasons.
ƒ
Take immediate countermeasures if there is a build-up of toxic
or suffocating gases!
ƒ
Clean the device thoroughly. Disinfect devices that are used in
fluids hazardous to health!
ƒ
Make sure that there is no risk of explosion when carrying out
any type of welding work or work with electrical devices.
2.8

During operation

ƒ
Wear the following protective equipment:
Safety shoes
Ear protection (in accordance with the notice of the work
regulations)
ƒ
Work area of the device is not a recreational area. No persons
are allowed in the work area during operation.
ƒ
The operator must immediately report any faults or irregularit-
ies to their line manager.
ƒ
If safety-endangering defects occur, the operator must imme-
diately deactivate the device:
Malfunction of the safety and monitoring device
Damage to the housing parts
Damage to the electrical equipment
ƒ
Never reach into the suction port. The rotating parts can crush
and sever limbs.
ƒ
If the motor emerges during operation, the motor housing can
heat up to above 40 °C (104 °F).
ƒ
Open all gate valves in the piping on the suction and pressure
side.
ƒ
Ensure minimum water submersion through dry-running pro-
tection.
ƒ
Under normal operating conditions, the sound pressure level of
the device is below 85 dB(A). However, the actual sound-pres-
sure level depends on several factors:
Installation depth
Installation
Fixation of accessories and pipe
Duty point
Immersion depth
ƒ
If the device is operated under normal operating conditions,
the operator must measure the sound pressure. Ear protection
en
7

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rexa cut gi03.31/s-m15-2-523/p6081536

Table of Contents