Motor protection and activation types Commissioning 6.1. Electrical system 6.2. Rotation control 6.3. Level control 6.4. Operation in potentially explosive areas 6.5. Commissioning 6.6. Conduct during operation Decommissioning/disposal 7.1. Temporary decommissioning 7.2. Decommissioning for maintenance work or storage Installation and operating instructions Wilo-Rexa PRO...
In general, repairs should only be carried out by Wilo It contains regulations and drawings which may not customer service. be reproduced or distributed, either completely or in part, or used for any competitive purpose without 1.5.6.
Furthermore, if such work is being carried out outdoors, it must be canceled if the weather Prohibition symbol, for example, Keep out! conditions worsen. Installation and operating instructions Wilo-Rexa PRO...
Cellphones and other mobile radio equipment may rosiveness, abrasiveness, dry matter content, and cause malfunctions in the system. in many other aspects. Generally, our pumps can be used for many applications. Please note that if requirements change (density, viscosity, or general WILO SE 2015-07 V05 Letter...
Wilo-Rexa PRO… submersible pumps are suitable We recommend that the end user takes an addition- for pumping the following fluids, in intermittent or permanent operation: al measurement at the workplace once the pump is running at its duty point and under all operating •...
3.4.1. Operating mode S1 (permanent operation) The seal for the fluid and the motor compart- The pump can operate continuously at the rated ment is made via two mechanical seals. The sealing load without exceeding the permissible tempera- chamber between the mechanical seals is filled with ture. environmentally safe medicinal white oil. WILO SE 2015-07 V05 Letter...
1 year. The pump should be free cable end cleaned thoroughly before it is put into temporary • Three phase version with storage. • bare cable end • with CEE plug WILO SE 2015-07 V05 Letter...
Prior to commissioning, the fill level in the seal- a suitable ventilation system and/or by placing the ing chamber should be checked and topped up, if Installation and operating instructions Wilo-Rexa PRO...
There is a risk of injury! Wear is to be installed outside potentially explosive areas the necessary protective clothing, such as pro- in such a way that it is protected from submersion. tective gloves. WILO SE 2015-07 V05 Letter...
Page 16
The housing parts can heat up to well above 104 °F (40 °C). There is a risk of burns! After DN 80 24 in (615 mm) switching it off, let the pump cool down to am- DN 100 24 in (615 mm) bient temperature. Installation and operating instructions Wilo-Rexa PRO...
Page 17
In addition, the pump connec- move freely in the operating area. tion to the pipe system must be free of stress and • The water level must not fall below the minimum. WILO SE 2015-07 V05 Letter...
Before connecting the power supply cable, the accordance with locally applicable regulations. insulation resistance must be tested. This can be measured with an insulation tester (measuring volt- age = 1000 V): • On initial commissioning: insulation resistance may not be less than 20 MΩ. Installation and operating instructions Wilo-Rexa PRO...
Page 19
Wire number Terminal Designation Connection WITHOUT capacitor switchgear If the unit is connected without a capacitor switch- gear, the two capacitors have to be present in the Line power switchgear. The following capacitor sizes need to be used here: • Start capacitor: 70 µF, 440 V, 60 Hz • Operating capacitor: 35 µF, 440 V, 60 Hz WILO SE 2015-07 V05 Letter...
"preliminary warning" may be issued, tion be set 5% above the current measured at the when the high threshold is reached, the motor duty point. must switch off. Installation and operating instructions Wilo-Rexa PRO...
6.2.2. If the direction of rotation is incorrect commissioning the pump, the following points must If the direction of rotation is incorrect for direct be observed: start motors, two phases must be swapped. In the case of motors with star-delta starting, the con- WILO SE 2015-07 V05 Letter...
These can result in crushing and • Max. immersion depth amputation of limbs. Never reach into the hy- • Clean the pipe system on the pressure side (hose, draulics when the machine is in operation. piping) – flush with clean water to prevent de- posits forming clogging. Installation and operating instructions Wilo-Rexa PRO...
For pumps in stationary dry well installation, the eration. For extended downtime, a regular (monthly suction- and pressure-side slide valves have to be to quarterly) 5 minute test run should be carried closed before removal. Note that the fluid in the hy- out. draulics housing will escape during removal. Suitable WILO SE 2015-07 V05 Letter...
7.5.1. Operating materials Any other work and/or alterations to the con- struction may only be carried out by Wilo cus- Oils and lubricants must be collected in suitable tomer service. vessels and disposed of in accordance with local directives.
• Esso MARCOL 52* or 82* Under harsh operating conditions, the specified • BP WHITEMORE WOM 14* maintenance intervals must be shortened accord- ingly. In this case, please contact Wilo customer ser- • Texaco Pharmaceutical 30* or 40* vice. If using the pump under harsh conditions, we All oil types marked with “*” are approved for use also recommend signing a maintenance contract.
The cables may only be replaced by Wilo cus- After the pump is switched off, the oil is still hot tomer service or an authorized or certified service and pressurized.
• Consult the manufacturer Inlet blocked Two-phase operation • Clean the supply line, slide valve, suction piece, • Have a specialist inspect the connection and cor- suction port, or suction strainer rect it as necessary WILO SE 2015-07 V05 Letter...
The following general measures could help to reduce or avoid faults: Further steps for troubleshooting If the points listed here do not rectify the fault, • Keep within the thresholds stated in IEC 60034-17 contact Wilo customer service, who can assist you for the voltage peaks and rise rate (output filters further as follows: may be necessary). • Telephone or written support from Wilo customer •...
The following connection values must be complied company, in accordance with locally applicable with: regulations. • Max. 30 Vrms (60 V peak) WILO SE 2015-07 V05 Letter...
• The mounted accessories must be approved for centers certified by the manufacturer. use on Ex pumps. 10.3. Spare parts Spare parts can be ordered from Wilo customer RISK of fatal injury due to explosion! service. To avoid return queries and incorrect orders, the serial and/or article number should always be The housing of the hydraulics must be fully supplied.