Summary of Contents for Wilo Padus UNI

  • Page 1 Pioneering for You Wilo-Padus UNI en Installation and operating instructions · 6084248 • Ed.02/2019-02...
  • Page 3: Table Of Contents

    Transport..........................................  11 Storage .......................................... 12 6 Installation and electrical connection .......................... 12 Personnel qualifications.................................... 12 Installation types...................................... 12 Operator responsibilities.................................... 12 Installation ........................................ 13 Electrical connection ......................................  15 7 Commissioning.................................. 17 Personnel qualifications.................................... 17 Installation and operating instructions Wilo-Padus UNI...
  • Page 4 Maintenance measures .................................... 21 10 Faults, causes and remedies .............................. 23 11 Spare parts.................................... 25 12 Disposal.................................... 25 12.1 Oils and lubricants...................................... 25 12.2 Protective clothing ...................................... 25 12.3 Information on the collection of used electrical and electronic products.................... 25 WILO SE 2019-02...
  • Page 5: General Information

    Failure to follow the instructions can lead to (serious) injuries! Improper use ƒ ƒ CAUTION! Incorrect storage or transport ƒ Failure to follow the instructions can lead to property damage Incorrect installation or dismantling and a possible total loss. ƒ Insufficient maintenance Installation and operating instructions Wilo-Padus UNI...
  • Page 6: Personnel Qualifications

    Motor protection switch ƒ Be instructed about locally applicable regulations governing Make provision for an on-site motor protection switch for accident prevention. devices without a plug! The minimum requirement is a thermal relay/motor protection switch with temperature compensation, WILO SE 2019-02...
  • Page 7: Use In Fluids Hazardous To Health

    Immersion depth – ƒ If the device is operated under normal operating conditions, Safety gloves for protection against cuts the operator must measure the sound pressure. Ear protection – Safety helmet (when using lifting equipment) Installation and operating instructions Wilo-Padus UNI...
  • Page 8: Maintenance Tasks

    Make sure that the personnel is relevantly trained for the spe- tions! The operator must make sure that the person- cified work. nel have received and read the work regulations! ƒ Provide the necessary protective equipment and make sure that the personnel wears it. WILO SE 2019-02...
  • Page 9: Product Description

    Strainer cially available shock-proof or CEE sockets and is not overflow- Connection cable proof. 4.1.1 Hydraulics Centrifugal hydraulics with open, multi-channel impeller and ver- tical threaded connection on the pressure side. The hydraulics are Installation and operating instructions Wilo-Padus UNI...
  • Page 10: Monitoring Devices

    Specified value (e.g. Type key S3 25 %) relates to the operating time. The switching cycle has a Example: Wilo-Padus UNI M05B/T15-540/A duration of 10 min. Series If two values (e.g. S3 25 %/120 s) are specified, the first value relates to the operating time.
  • Page 11: Accessories

    The stability of the lifting equipment must be ensured during operation. ƒ When using lifting equipment, a second person must be present to coordinate the procedure if required (e.g. if the op- erator’s field of vision is blocked). Installation and operating instructions Wilo-Padus UNI...
  • Page 12: Storage

     6 months). This prevents locking of the bearings and renews complete and correct. the lubrication film of the mechanical seal. WARNING! There is a risk of injury due to sharp edges on the impeller and suction port! WILO SE 2019-02...
  • Page 13: Installation

    Ensure that the pump cannot fall over or slip ƒ Use the handle for lifting, lowering and transporting the pump. away! Never carry or drag the pump by the power supply cable! 2. Unscrew the screw plug. Installation and operating instructions Wilo-Padus UNI...
  • Page 14 The strainer filters coarse solids out of the fluid and enables se- 5. Lay the connection cable properly. CAUTION! Do not cure standing if placed on a solid load bearing surface. This allows damage the connection cable! the pump to be installed anywhere in the operating space/install- WILO SE 2019-02...
  • Page 15: Electrical Connection

    6.5.2 Maintenance tasks without fluid and air from entering the hydraulics. The minimum Carry out the following maintenance tasks prior to installation: permissible fill level must be determined with the help of a signal Installation and operating instructions Wilo-Padus UNI...
  • Page 16 DANGER! If the pump is connected directly to the switchgear, evaluation relay. dismantle the plug and arrange for the electrical connection to Connection values: max. 250 V (AC), 2.5 A, cos φ = 1 be carried out by a qualified electrician! When the threshold is reached, deactivation must take place. WILO SE 2019-02...
  • Page 17: Commissioning

    A qualified electrician checks the rotating field at the mains con- right again before activating them. Securely attach the pump with nection with a rotating field-test device. For the correct direction screws in case of difficult surfaces. Installation and operating instructions Wilo-Padus UNI...
  • Page 18: During Operation

    Motor housing can become hot during operation. It may cause burns. Allow the pump to cool down at Operator responsibilities ambient temperature after switching it off! ƒ Locally applicable accident prevention and safety regulations of trade associations. WILO SE 2019-02...
  • Page 19: Shut-Down

    5. Lift the pump from the operating space. CAUTION! The power supply cable may be squeezed and damaged when setting the pump down! Pay attention to the power supply cable when setting the pump down! Installation and operating instructions Wilo-Padus UNI...
  • Page 20: Maintenance And Repair

    In order to completely drain the pump housing, lie it nel have received and read the work regulations! down on its side for approx. 5 minutes. Place the pres- sure port face down. 8.4.2.1 Cleaning the strainer The strainer can be removed for cleaning. WILO SE 2019-02...
  • Page 21: Personnel Qualifications

    Oil types ive gloves must be worn to protect from cuts. Medicinal white oil is filled into the sealing chamber ex-factory. The following oil types are recommended when changing the oil: ƒ Aral Autin PL* Installation and operating instructions Wilo-Padus UNI...
  • Page 22 Have the connection cable replaced by injuries, the following instructions must be observed: Wilo customer service. Only operate the pump up again once the • Allow the motor to cool down to the ambient damage has been properly remedied! temperature before opening the screw plugs.
  • Page 23: Faults, Causes And Remedies

    Improper conduct when carrying out electrical work Clearance adjustment can lead to death due to electric shock! Electrical work must be carried out by a qualified electrician in Dial accordance with the locally applicable regulations. Pointer (▲) Installation and operating instructions Wilo-Padus UNI...
  • Page 24 1. Motor protection switch set incorrectly. trician. ⇒ Have the adjustment of the trigger checked and 5. Air cushion in the pipe system. corrected by a qualified electrician. ⇒ Vent the pipe system. 2. Increased power consumption due to major voltage drop. WILO SE 2019-02...
  • Page 25: Spare Parts

    Please consult your local municipality, the nearest waste disposal 7. Motor bearings have worn. site, or the dealer who sold the product to you for information on ⇒ Inform customer service; send the pump back to the factory for overhauling. Installation and operating instructions Wilo-Padus UNI...
  • Page 26 Disposal proper disposal. Further recycling information at www.wilo‑recycling.com. WILO SE 2019-02...
  • Page 27 WILO Pompa Sistemleri Jakarta Timur, 13950 Sistemas Hidraulicos Lda. San. ve Tic. A.S¸ T +62 21 7247676 4475-330 Maia 34956 İstanbul citrawilo@cbn.net.id T +351 22 2080350 T +90 216 2509400 bombas@wilo.pt wilo@wilo.com.tr Further subsidiaries, representation and sales offices on www.wilo.com Oktober 2018...
  • Page 28 WILO SE Nortkirchenstr. 100 44263 Dortmund Germany T +49 (0)231 4102-0 T +49 (0)231 4102-7363 wilo@wilo.com Pioneering for You www.wilo.com...