Installation
WALL-MOUNT TYPICAL
INSTALLATION
KEY FOR FIG. 4
A
Air Supply Line
B
Bleed-Type Master Air Valve
(required for pump)
C
Air Regulator
D
Air Line Quick Disconnect
E
Master Air Valve (for accessories)
F
Air Line Filter
G
Fluid Suction Line
J
Fluid Drain Valve (required)
K
Fluid Shutoff Valve
L
Fluid Line
M
Wall Mounting Bracket
Y
Ground Wire (required; see page 4
for installation instructions)
Fig. 4
Changing the Orientation of the Fluid Inlet and
Outlet Ports
On aluminum pumps, the fluid inlet and outlet manifolds
have threaded ports on both ends. The pump is shipped with
a plug installed in one end of each manifold, and the opposite
end open. See Fig. 5. To change the orientation of the inlet
and/or outlet port, remove the plug from one end of a man-
ifold and install it in the opposite end.
On stainless steel pumps, the fluid inlet and outlet man-
ifolds have threaded ports on one end only. The pump is
shipped with the ports facing the same direction. To reverse
the orientation of the ports:
1.
Remove the screws and nuts holding the inlet and/or
outlet manifold to the covers.
2.
Reverse the manifold and reattach. Install the screws
and torque to 14–17 NSm. See Torque Sequence, page
28.
B
E
F
C
D
G
KEY
N
1/2 npt(f) Air Inlet Port
P
Muffler; Air Exhaust Port is 3/4 npt(f)
R*
1 in. bspt Fluid Inlet Port
S*
1 in. bspt Fluid Outlet Port
106 Manifold and Cover Screws
3
Air Valve Screws
3
2
N
P
Fig. 5
On pumps 810.0191, 810.0192, 810.0193, and 810.0194
*
the inlet and outlet fluid ports are 1 in. npt threads.
L
K
A
J
Y
M
1
Torque to 14–17 NSm.
See Torque Sequence,
page 28.
2
Torque to 5.6–6.8 NSm.
02649B
106
1
S
106
1
R
02632B
819.4470
7