All 230/208 volt units are equipped with power cords.
NOTE: Use Copper Conductors ONLY
Wire sizes are per NEC, check local
codes for overseas applications
Table 1
250 V Receptacles and Fuse Types
AMPS
RECEPTACLE
MANUFACTURER
Hubbell
P & S
GE
Arrow-Hart
TIME-DELAY TYPE
FUSE
(or HACR circuit breaker)
HACR — Heating, Air conditioning, Refrigeration
* May be used for 15 Amp applications if fused for 15 Amp
NOTE: 265 volt units are permanently connected.
Wire Size
Use ONLY wiring size recommended for single outlet branch circuit.
Fuse/Circuit
Use ONLY type and size fuse or HACR circuit breaker indicated on unit's rating plate. Proper
Breaker
current protection to the unit is the responsibility of the owner.
NOTE: A time delay fuse is provided with 265V units.
Grounding
Unit MUST be grounded from branch circuit through service cord to unit, or through separate ground
wire provided on permanently connected units. Be sure that branch circuit or general purpose outlet
is grounded.
Receptacle
The field supplied outlet must match plug on service cord and be within reach of service cord.
Refer to Table 1 for proper receptacle and fuse type. Do NOT alter the service cord or plug. Do
NOT use an extension cord.
Wire Sizing
Use recommended wire size given in Table 2 and install a single branch circuit. All wiring must
comply with local and national codes. NOTE: Use copper conductors only.

Electrical Rating Tables

15
20 *
PART NUMBERS
5661
5461
5661
5871
GE 4069-1 GE4182-1
5661
5861
15
20
Table 2
30
Recommended branch circuit wire sizes
maximum circuit
9330
5930
GE4139-3
5700
30
Electric shock hazard.
Turn off electric power before service or installation.
All electrical connections and wiring MUST be installed by a qualified electrician
and conform to the National Electrical Code and all local codes which have
jurisdiction.
Failure to do so can result in property damage, personal injury and/or death.
Nameplate
AWG Wire size**
breaker size
15
20
30
AWG — American Wire Gauge
* Single circuit from main box
** Based on copper wire, single insulated
conductor at 60°C
14
12
10
7