Download Print this page
Sun Microsystems Netra st D130 Installation And Maintenance Manual
Sun Microsystems Netra st D130 Installation And Maintenance Manual

Sun Microsystems Netra st D130 Installation And Maintenance Manual

Hide thumbs Also See for Netra st D130:

Advertisement

Quick Links

Netra st D130 Installation and
Maintenance Manual
901 San Antonio Road
Palo Alto, , CA 94303-4900
Part No: 806-1489-10
November 1999, Revision A

Advertisement

loading
Need help?

Need help?

Do you have a question about the Netra st D130 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Sun Microsystems Netra st D130

  • Page 1 Netra st D130 Installation and Maintenance Manual 901 San Antonio Road Palo Alto, , CA 94303-4900 Part No: 806-1489-10 November 1999, Revision A...
  • Page 2 USA 650 960-1300 Fax 650 969-9131...
  • Page 3 Netra st D130 Installation and Maintenance Manual Part No: 806-1489-10 November 1999, Revision A...
  • Page 4 Sun, Sun Microsystems, le logo Sun, SunStore, AnswerBook2, docs.sun.com, Netra, Solstice DiskSuite, SunSwift, et Solaris sont des marques de fabrique ou des marques déposées, ou marques de service, de Sun Microsystems, Inc. aux Etats-Unis et dans d’autres pays. Toutes les marques SPARC sont utilisées sous licence et sont des marques de fabrique ou des marques déposées de SPARC International, Inc.
  • Page 5: Table Of Contents

    Contents Preface viii Regulatory Compliance Statements 1 FCC Class A Notice 1 FCC Class B Notice 2 DOC Class A Notice - Avis DOC, Classe A 3 DOC Class B Notice - Avis DOC, Classe B 3 BSMI Class A Notice 4 Declaration of Conformity 5 EMC 5 USA—FCC Class A 5...
  • Page 6 Precauciones de seguridad 20 Símbolos 20 Modificaciones en el equipo 21 Ubicación de un producto Sun 21 Cumplimiento de la normativa SELV 22 Conexión del cable de alimentación eléctrica 22 Netra st D130 Installation and Maintenance Manual ♦ November 1999, Revision A...
  • Page 7 Assembling the DC Input Power Cable 40 Required Connection Materials 40 To Assemble the DC Input Power Cable 41 To Install the Strain Relief Housings 45 Isolating the Chassis Ground Connection 47 Installing the Netra st D130 Storage Enclosure 49 Contents...
  • Page 8 Removing and Replacing a Disk Drive 65 To Remove a Disk Drive 66 To Replace a Disk Drive 67 System Specifications 69 Physical Specifications 69 Electrical Specifications 70 Environmental Specifications 70 Index 73 Netra st D130 Installation and Maintenance Manual ♦ November 1999, Revision A...
  • Page 9: Preface

    Chapter 6 gives instructions for installing the Netra st D130 storage enclosure. Chapter 7 gives the procedures for removing, replacing, or adding disk drives to the Netra st D130 storage enclosure. Appendix A gives the system specifications for the Netra st D130 storage enclosure. Using UNIX Commands ®...
  • Page 10: Typographic Conventions

    To delete a file, type rm filename. Shell Prompts Shell Prompts TABLE P–2 Shell Prompt C shell machine_name% C shell superuser machine_name# Netra st D130 Installation and Maintenance Manual ♦ November 1999, Revision A...
  • Page 11: Related Documentation

    TABLE P–3 Application Title Part Number Late-breaking information Netra st D130 Product Notes 806-1490-10 Accessing Sun Documentation Online The docs.sun.com web site enables you to access Sun technical documentation on the Web. You can browse the docs.sun.com archive or search for a specific book title or subject at: http://docs.sun.com...
  • Page 12 Please include the part number (806-1489-10) of your document in the subject line of your email. Netra st D130 Installation and Maintenance Manual ♦ November 1999, Revision A...
  • Page 13: Regulatory Compliance Statements

    CHAPTER Regulatory Compliance Statements Your Sun product is marked to indicate its compliance class: 4 Federal Communications Commission (FCC) — USA 4 Department of Communications (DOC) — Canada 4 Voluntary Control Council for Interference (VCCI) — Japan Please read the appropriate section that corresponds to the marking on your Sun product before attempting to install the product.
  • Page 14: Fcc Class B Notice

    FCC radio frequency emission limits. Modifications: Any modifications made to this device that are not approved by Sun Microsystems, Inc. may void the authority granted to the user by the FCC to operate this equipment.
  • Page 15: Doc Class A Notice - Avis Doc, Classe A

    DOC Class A Notice - Avis DOC, Classe This Class A digital apparatus meets all requirements of the Canadian Interference-Causing Equipment Regulations. Cet appareil numérique de la classe A respecte toutes les exigences du Règlement sur le matériel brouilleur du Canada. DOC Class B Notice - Avis DOC, Classe This Class B digital apparatus meets all requirements of the Canadian Interference-Causing Equipment Regulations.
  • Page 16: Bsmi Class A Notice

    BSMI Class A Notice The following statement is applicable to products shipped to Taiwan and marked as Class A on the product compliance label. Netra st D130 Installation and Maintenance Manual ♦ November 1999, Revision A...
  • Page 17: Declaration Of Conformity

    Declaration of Conformity Agency Model Number: CYT1A (AC version) CYT1D (DC version) Product Name: Netra st D130 This product has been tested and complies with the following rules and requirements. USA—FCC Class A This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: 1.
  • Page 18: Safety

    EN60950 - Evaluated to all CB Scheme Country Deviations Supplementary Information This product was tested and complies with all the requirements for the CE Mark (when connected to a Sun workstation or server). Netra st D130 Installation and Maintenance Manual ♦ November 1999, Revision A...
  • Page 19 Symanski DATE Shades DATE Manager, Product Compliance Quality Assurance Manager Sun Microsystems, Inc. Sun Microsystems Scotland, Limited 901 San Antonio Road, M/S UMPK15-102 Springfield, Linlithgow Palo Alto, CA 94303, USA West Lothian, EH49 7LR Scotland, United Kingdom Tel: 650-786-3255 Tel: 0506-670000...
  • Page 20 Netra st D130 Installation and Maintenance Manual ♦ November 1999, Revision A...
  • Page 21: Safety Agency Compliance Statements

    CHAPTER Safety Agency Compliance Statements Read this section before beginning any procedure. The following text provides safety precautions to follow when installing a Sun Microsystems product. Safety Precautions For your protection, observe the following safety precautions when setting up your equipment: 4 Follow all cautions and instructions marked on the equipment.
  • Page 22: Modifications To Equipment

    Standby – The On/Standby switch is in the standby position. Modifications to Equipment Do not make mechanical or electrical modifications to the equipment. Sun Microsystems is not responsible for regulatory compliance of a modified Sun product. Netra st D130 Installation and Maintenance Manual ♦ November 1999, Revision A...
  • Page 23: Placement Of A Sun Product

    Placement of a Sun Product Caution – Do not block or cover the openings of your Sun product. Never place a Sun product near a radiator or heat register. Failure to follow these guidelines can cause overheating and affect the reliability of your Sun product.
  • Page 24: System Unit Cover

    Caution – Netra st D130 units are designed to work with either AC or DC power, depending on the power pack included with the product. Units designed to work with DC power are shipped with a connector to be used with a customer supplied 48V power cord for the customer to connect to the DC power source.
  • Page 25: Einhaltung Sicherheitsbehördlicher Vorschriften

    Einhaltung sicherheitsbehördlicher Vorschriften Auf dieser Seite werden Sicherheitsrichtlinien beschrieben, die bei der Installation von Sun-Produkten zu beachten sind. Sicherheitsvorkehrungen Treffen Sie zu Ihrem eigenen Schutz die folgenden Sicherheitsvorkehrungen, wenn Sie Ihr Gerät installieren: 4 Beachten Sie alle auf den Geräten angebrachten Warnhinweise und Anweisungen. 4 Vergewissern Sie sich, daß...
  • Page 26: Aufstellung Von Sun-Geräten

    Achtung – Der arbeitsplatzbezogene Schalldruckpegel nach DIN 45 635 Teil 1000 beträgt 70Db(A) oder weniger. Einhaltung der SELV-Richtlinien Die Sicherung der I/O-Verbindungen entspricht den Anforderungen der SELV-Spezifikation. Netra st D130 Installation and Maintenance Manual ♦ November 1999, Revision A...
  • Page 27: Anschluß Des Netzkabels

    Achtung – Trennen Sie alle Stromkabel, um die gesamte Stromzufuhr zu diesem Gerät zu unterbrechen. Achtung – Netra st D130-Einheiten wurden für die Stromversorgung mit Wechsel- oder Gleichstrom entwickelt. Die Stromversorgung hängt vom mitgeliefertem Netzteil ab. Die Einheiten, die mit Gleichstrom betrieben werden, werden mit einem 48V-Stecker geliefert, um dem Kunden den Anschluß...
  • Page 28: Gehäuseabdeckung

    Vous pourriez vous trouver en présence de hautes tensions dangereuses. Tout objet conducteur introduit de la sorte pourrait produire un court-circuit qui entraînerait des flammes, des risques d’électrocution ou des dégâts matériels. Netra st D130 Installation and Maintenance Manual ♦ November 1999, Revision A...
  • Page 29: Symboles

    Symboles Vous trouverez ci-dessous la signification des différents symboles utilisés : Attention: – risques de blessures corporelles et de dégâts matériels. Veuillez suivre les instructions. Attention: – surface à température élevée. Evitez le contact. La température des surfaces est élevée et leur contact peut provoquer des blessures corporelles.
  • Page 30: Positionnement D'un Produit Sun

    été livrée équipée d’un cordon d’alimentation à trois fils (avec prise de terre). Pour écarter tout risque d’électrocution, branchez toujours ce cordon dans une prise mise à la terre. Netra st D130 Installation and Maintenance Manual ♦ November 1999, Revision A...
  • Page 31: Couvercle

    Attention: – Pour mettre le système hors tension, il est impératif de débrancher tous les cordons d"alimentation. Attention: – les unités Netra st D130 sont conçues pour fonctionner avec une alimentation en courant alternatif ou en courant continu, selon le bloc d’alimentation inclus avec le produit.
  • Page 32: Normativas De Seguridad

    Precaución – Existe el riesgo de lesiones personales y daños al equipo. Siga las instrucciones. Precaución – Superficie caliente. Evite el contacto. Las superficies están calientes y pueden causar daños personales si se tocan. Netra st D130 Installation and Maintenance Manual ♦ November 1999, Revision A...
  • Page 33: Modificaciones En El Equipo

    Precaución – Voltaje peligroso presente. Para reducir el riesgo de descarga y daños para la salud siga las instrucciones. Encendido – Aplica la alimentación de CA al sistema. Según el tipo de interruptor de encendido que su equipo tenga, es posible que se utilice uno de los siguientes símbolos: Apagado - Elimina la alimentación de CA del sistema.
  • Page 34: Cumplimiento De La Normativa Selv

    Precaución – Para cortar el suministro eléctrico de esta unidad, desconecte todos los cables de alimentación. Precaución – El diseño de las unidades Netra st D130 permite su funcionamiento con alimentación de CA o CC, según el tipo de alimentación para el que esté preparado su producto. Las unidades destinadas a su funcionamiento con CC se entregan con un conector que debe usarse con un cable de alimentación de 48 V del cliente, a fin de que...
  • Page 35: Tapa De La Unidad Del Sistema

    Precaución – El interruptor de encendido de este producto funciona exclusivamente como un dispositivo de puesta en espera. El enchufe de la fuente de alimentación está diseñado para ser el elemento primario de desconexión del equipo. El equipo debe instalarse cerca del enchufe de forma que este último pueda ser fácil y rápidamente accesible.
  • Page 36: Gost-R Certification Mark

    GOST-R Certification Mark Netra st D130 Installation and Maintenance Manual ♦ November 1999, Revision A...
  • Page 37: Netra St D130 Storage Enclosure Overview

    For information on the drives, refer to the documents that you received with them. The Netra st D130 disk unit is a single-ended UltraSCSI unit that is 1.73 inches (or 1U) in height. The thinness of the unit enables you to stack up to 40 units in a single 72-inch tall rack.
  • Page 38: Components At The Front Of The Enclosure

    The front panel can be removed to allow access to the hard disk drives. The Netra st D130 storage enclosure can accept up to three 1-inch high drives. Figure 4–2 Removing the Front Panel Netra st D130 Installation and Maintenance Manual ♦ November 1999, Revision A...
  • Page 39: Front Panel Leds

    Disk Drive Solid green A disk drive is present in No action is necessary. that slot but is not active. The Disk Drive LED also gives the SCSI ID for that disk drive. Netra st D130 Storage Enclosure Overview...
  • Page 40: Components At The Back Of The Enclosure

    Components at the Back of the Enclosure Figure 4–4 Netra st D130, Rear View Power Switch The Netra st D130 storage enclosure has one rocker power switch to control the power supply. Netra st D130 Installation and Maintenance Manual ♦ November 1999, Revision A...
  • Page 41: Scsi Id Switch

    AC or DC input will continue to flow to the power supply until you unplug the power cable from the electrical outlet. SCSI ID Switch The SCSI ID switch sets the SCSI IDs for the disk drives. Figure 4–6 SCSI ID Switch Netra st D130 Storage Enclosure Overview...
  • Page 42: Back Panel Leds

    Refer to Table 4–1 for more information. Auto Termination Indication LEDs The Auto Termination Indication LEDs indicate if the Netra st D130 storage enclosure is part of an UltraSCSI, wide SCSI or narrow SCSI daisy-chain. It also indicates its position in the daisy-chain.
  • Page 43 Note - UltraSCSI devices (such as the Netra st D130 storage enclosure) at the end of a daisy-chain do not require a terminator, but some wide SCSI devices at the end of a daisy-chain do require a terminator. Refer to the documentation that came with your wide SCSI device to determine if it needs a terminator or not.
  • Page 44: Internal Components

    Auto Termination Indication LEDs Lit in a Narrow SCSI Daisy-Chain Internal Components Power Supply The Netra st D130 storage enclosure has a single power supply that provides power to the internal components. The power supply in your system is either AC- or DC-powered.
  • Page 45: Cooling System

    The power supply on the DC version converts incoming -48 VDC voltage to outgoing DC voltages. The DC version has two connectors so you can connect a single Netra st D130 storage enclosure to two different -48V DC power sources. Each DC power source should have a 10-amp circuit breaker.
  • Page 46: Disk Drives

    55 ˚ Celsius (131 ˚ Fahrenheit). Disk Drives The disk drives in the Netra st D130 storage enclosure are all hot-pluggable. See the documentation that comes with your system for information about the drives Netra st D130 Installation and Maintenance Manual ♦ November 1999, Revision A...
  • Page 47: Foam Fillers

    SCSI ID switch at the rear of the enclosure. Refer to the drive LEDs on the front of the Netra st D130 storage enclosure or the SCSI ID switch at the rear of the enclosure to determine the SCSI IDs that you have assigned to the drives in your enclosure.
  • Page 48 Netra st D130 Installation and Maintenance Manual ♦ November 1999, Revision A...
  • Page 49: Electrical Requirements And Cable Assembly

    Electrical Requirements and Cable Assembly This chapter provides electrical information for both the AC- and DC-powered versions of the Netra st D130 storage enclosure. This chapter is organized as follows: 4 “AC Source Site Requirements” on page 37 4 “DC Source Site Requirements ” on page 38 4 “Assembling the DC Input Power Cable”...
  • Page 50: Dc Source Site Requirements

    4 Overcurrent protection devices must be provided as part of each host equipment rack. 4 Circuit breakers are located between the AC source and the Netra st D130 storage enclosure. 4 Circuit breakers must not trip when presented with inrush current of 100 amps lasting 5 ms.
  • Page 51: Overcurrent Protection Requirements

    4 Capable of providing up to 200 watts of continuous power per feed pair Note - The DC version of the Netra st D130 storage enclosure must be installed in a restricted access location. Per the intent of the National Electrical Code, a restricted access location is an area intended for qualified or trained personnel only and has...
  • Page 52: Assembling The Dc Input Power Cable

    Assembling the DC Input Power Cable Follow these instructions to assemble the DC input power cable, which will be used to connect the DC power supply in your Netra st D130 storage enclosure to the DC power source. Required Connection Materials...
  • Page 53: To Assemble The Dc Input Power Cable

    Figure 5–2 Strain Relief Housing Figure 5–3 Cage Clamp Operating Lever The following figure shows the power connector on the DC power supply. Figure 5–4 Power Connector on the DC Power Supply To Assemble the DC Input Power Cable 1. Turn off power to the DC power source through the circuit breakers. Caution - Do not proceed with these instructions until you have turned off the power to the DC power source through the circuit breakers.
  • Page 54 DC connector where you want to insert the first wire and press down on the cage clamp operating lever. This opens the cage clamp for this section of the DC connector. Netra st D130 Installation and Maintenance Manual ♦ November 1999, Revision A...
  • Page 55 Figure 5–6 Opening the DC Connector Cage Clamp Using the Cage Clamp Operating Lever You can also open the DC connector cage clamp by inserting a small flat-blade screwdriver into the rectangular hole directly above the hole in the DC connector where you want to insert the first wire and pressing down on the screwdriver.
  • Page 56 7. Repeat Step 5 on page 42 and Step 6 on page 44 for the other two wires to complete the assembly of the DC input power cable. Netra st D130 Installation and Maintenance Manual ♦ November 1999, Revision A...
  • Page 57: To Install The Strain Relief Housings

    8. Repeat Step 3 on page 42 through Step 7 on page 44 to create a second DC input power cable. The first DC input power cable should be connected to DC power source A and the second DC input power cable should be connected to DC power source B. If you need to remove a wire from the DC connector, insert the cage clamp operating lever or a small screwdriver into the slot directly above the wire and press down (Figure 5–6 and Figure 5–7).
  • Page 58 Housing 3. Get the tie wrap and insert it into the bottom portion of the strain relief housing. Figure 5–11 Securing the Wires to the Strain Relief Housing Netra st D130 Installation and Maintenance Manual ♦ November 1999, Revision A...
  • Page 59: Isolating The Chassis Ground Connection

    Isolating the Chassis Ground Connection Every Netra st D130 storage enclosure is shipped out of the factory with the chassis ground connected to the common output return through two screws on the power supply at the rear of the enclosure. If you want to isolate this connection, follow the instructions in the Netra st D130 Product Notes.
  • Page 60 Netra st D130 Installation and Maintenance Manual ♦ November 1999, Revision A...
  • Page 61: Installing The Netra St D130 Storage Enclosure

    4 “Installing the Netra st D130 Storage Enclosure” on page 52 4 “Powering On and Off” on page 59 Hardware Requirements The following hardware is included with every Netra st D130 storage enclosure: 4 UltraSCSI cables 4 Power connections, depending on the type of storage enclosure: AC version –...
  • Page 62: Preparing For Installation

    Netra st D130 storage enclosure must be capable of UltraSCSI speeds. You can connect a Netra st D130 storage enclosure to a wide or narrow SCSI-capable host adapter, but in such a case, the enclosure performs at a lower speed.
  • Page 63 IDs for the disk drives in the Netra st D130 storage enclosure. Verify that the SCSI IDs that you want to use for the drives in your Netra st D130 storage enclosure are not being used already by your host system or by other peripherals connected to your host system.
  • Page 64 Figure 6–2 Netra st D130 Rear View (AC Version) 4. Determine if this Netra st D130 storage enclosure is at the beginning or the end of the SCSI chain. Netra st D130 Installation and Maintenance Manual ♦ November 1999, Revision A...
  • Page 65 The overall SCSI bus length cannot exceed 6 meters. The SCSI bus length for the cables inside the Netra st D130 storage enclosure is 1 meter. If you are connecting another type of peripheral in this daisy-chain, refer to the documentation that you received with that peripheral for its internal SCSI bus length.
  • Page 66 8. Determine if you need to install an external terminator at the end of the SCSI daisy-chain. 4 If the last device in the SCSI daisy-chain is a Netra st D130 storage enclosure or some other type of UltraSCSI device, do not install an external terminator on the device.
  • Page 67: Connecting The Power Cable

    Connecting the Power Cable The procedures for connecting the power cable vary depending on whether you have the AC or the DC version of the Netra st D130 system. 4 “AC Version” on page 56 4 “DC Version” on page 56...
  • Page 68 4. Tighten the two bolts to secure the grounding cable to the two lug nuts. 5. Secure the other end of the grounding cable to the earth ground in the building. Netra st D130 Installation and Maintenance Manual ♦ November 1999, Revision A...
  • Page 69 If you are installing the Netra st D130 storage enclosure in a rack, you can secure the grounding cable to a a proper grounding point on the rack, as long as the rack is properly grounded to the earth ground in the building.
  • Page 70 DC input power cable and gently disconnect the DC input power cable from the DC power supply. Figure 6–8 Disconnecting the DC Input Power Cable from the DC Connector Netra st D130 Installation and Maintenance Manual ♦ November 1999, Revision A...
  • Page 71: Powering On And Off

    2. Back up system files and data, if necessary. 3. Halt the operating system. 4. Press the power system switch on the storage enclosure to the standby position. 5. Verify that the System Power LED is off. Installing the Netra st D130 Storage Enclosure...
  • Page 72 Even with the power switch in the standby position, power remains connected to the enclosure, and potentially dangerous voltages is present in the power supply. You must unplug the power cable to completely remove power to the enclosure. Netra st D130 Installation and Maintenance Manual ♦ November 1999, Revision A...
  • Page 73: Adding A Disk Drive

    Adding, Removing, and Replacing Disk Drives This chapter gives hardware and software instructions for adding, removing, and replacing disk drives in a Netra st D130 storage enclosure. This chapter is organized as follows: 4 “Adding a Disk Drive” on page 61 4 “Removing and Replacing a Disk Drive”...
  • Page 74: To Add A Disk Drive

    Figure 7–1 Removing the Front Panel 2. Select any available slot in the Netra st D130 storage enclosure for the new disk drive. Make a note of which slot you choose for reference when you configure the software environment.
  • Page 75: Performing The Software Configuration Procedures

    When you add a disk drive, you must create a new device entry for the drive in the /devices, /dev/dsk, and /dev/rdsk hierarchies. The new drive is assigned a name associated with the slot in the Netra st D130 storage enclosure into which the drive was installed.
  • Page 76 For example, if the Netra st D130 storage enclosure is connected to a host adapter corresponding to controller c2, and a drive was added to the second slot in a Netra st D130 storage enclosure with the SCSI ID switch in the leftmost position (which assigns SCSI IDs 2, 3, and 4 to the drives inside the enclosure), the new drive appears as /dev/dsk/c2t3d0s[0-7] and /dev/rdsk/c2t3d0s[0-7].
  • Page 77: Removing And Replacing A Disk Drive

    The file system is ready to be used. Removing and Replacing a Disk Drive The Netra st D130 storage enclosure comes configured with 1-inch high drives. The procedure for removing and replacing the drives differs only in the software you use to control the disks.
  • Page 78: To Remove A Disk Drive

    If the Netra st D130 storage enclosure is running and a drive slot does not contain a disk drive or foam filler, the Netra st D130 storage enclosure will not cool properly and may overheat. If you are not replacing the disk drive immediately, you must install a foam filler in the empty slot.
  • Page 79: To Replace A Disk Drive

    To Replace a Disk Drive Note - You cannot mix and match capacities of disk drives in the Netra st D130 storage enclosure. 1. If necessary, refer to the documentation that came with your Veritas VxVM or Solstice DiskSuite software for any procedures that you might have to perform before you can replace the disk drive.
  • Page 80 Netra st D130 Installation and Maintenance Manual ♦ November 1999, Revision A...
  • Page 81: System Specifications

    APPENDIX System Specifications This appendix gives the system specifications for the Netra st D130 storage enclosure. 4 “Physical Specifications” on page 69 4 “Electrical Specifications” on page 70 4 “Environmental Specifications” on page 70 Physical Specifications Physical Specifications TABLE A–1...
  • Page 82: Electrical Specifications

    0 ˚ C to 40 ˚ C (32 ˚ F to 104 ˚ F) -25 ˚ C to 65 ˚ C (-13 ˚ F to 149 ˚ F) Storage Netra st D130 Installation and Maintenance Manual ♦ November 1999, Revision A...
  • Page 83 Environmental Specifications TABLE A–4 (continued) Climate Control Location Minimum to Maximum Range Transit -25 ˚ C to 65 ˚ C (-13 ˚ F to 149 ˚ F) -5 ˚ C to 55 ˚ C (23 ˚ F to 131 ˚ F) Short term (96 consecutive hrs) Operating Nonoperating...
  • Page 84 Netra st D130 Installation and Maintenance Manual ♦ November 1999, Revision A...
  • Page 85 Index description, 25 Disk Drive LED, 27 AC version disk drives connecting power cables, 55, 56 adding, 62 power requirements, 37, 38, 70, 71 description, 34 power supply, 32 naming conventions, 63 airflow requirements, 33 removing, 27, 66 Auto Termination Indication LED, 30 replacing, 67, 67 software configuration procedures, 63 back panel LEDs, 30...
  • Page 86 System Power LED, 27, 30 preparing the host system, 50, 52 System Summary Fault LED, 27, 30 product description, 25 removing a disk drive, 28, 61, 65 Netra st D130 Installation and Maintenance Manual ♦ November 1999, Revision A Index-74...