Disassemble The Center Section - Graco ChemSafe 1040 Instructions - Parts Manual

Air-operated diaphragm pump
Hide thumbs Also See for ChemSafe 1040:
Table of Contents

Advertisement

10. To remove the nuts (28) and bolts (24), use two
10 mm wrenches to hold on one side and turn
the other. The nuts (28) will come off of one side
only. Then remove the bolts (24).
NOTE: The nuts are permanently affixed to one
NOTE:
NOTE:
end of the bolts.
11. Remove the fluid cover retainers (9) and the fluid
covers (6) from the body (1).
Disassemble the
the Center
Disassemble
Disassemble
the
1. One diaphragm (25) and strike plate (4) should
screw off by hand. Slide the second diaphragm
and strike plate out with the shaft (5).
334795A
Center Section
Section
Center
Section
2. Inspect the o-ring seals (32) and glide shaft seals
(39). Replace as needed.
3. Carefully remove the cap plugs (37) from both
muffler locations.
4. Use a 4 mm Allen wrench to remove the screws
(16) and muffler caps (14).
5. Inspect the mesh baffle spacers (38) and felt
mufflers (15). Replace as needed.
6. Use a 19 mm socket and the supplied tool (42) to
remove the sleeve spool assembly (3).
Repair
19

Advertisement

Table of Contents
loading