Code 3 XTP Series Installation And Operation Instructions Manual page 3

Light heads
Table of Contents

Advertisement

Flash Patterns:
A variety of flash patterns may be chosen for the light head. The Multi Color light heads are split vertically as separate lighted areas that may
be chosen to operate alternately. The areas are denoted by: Primary color 1&3 (color1 on the left side and color3 on the right, typically the
same color) and Secondary color 2&4 (color2 on the left side and color4 on the right, typically the same color). This allows for patterns that
flash right-left using various multiple color combinations.
A separate flash pattern may be assigned for the power wires red, white, or both connected together and the pattern operated depending
which wire or wires are energized. Power the red or the white wires (or both together) then use the pattern select blue wire (touch to ground)
to select the chosen flash pattern from the list below. See the legend at the top of the pattern list for compliance with various standards.
Pattern Select Operation:
The light head flash pattern may be changed by touching the Blue wire to ground for the following intervals (while the light head is flashing):
NOTE: The blue wire must be disconnected from any voltage when not activating DIM nor changing flash patterns.
- When the light head signal becomes steady, disconnect the Blue wire and the flash pattern will increment by one pattern.
- When the light head signal becomes steady, then goes off, disconnect the Blue wire and the flash pattern will decrement by one pattern.
- When the light head signal becomes steady, then goes off, then becomes steady again, disconnect the Blue wire and the flash pattern will
reset to the factory default pattern.
- When the light head signal becomes steady, then goes off, then becomes steady again, then goes off again, disconnect the Blue wire and
the flash pattern will become set to the steady burn mode.
Flash Patterns XTP4DS Multi Color:
For patterns that meet SAE J595 Class1 requirements for Red, Blue, Amber, and White, see S in chart!
For patterns that meet California Title 13 Class B requirements for Red, Blue, and Amber, see C in chart!
For patterns that meet ECE R65 Class 2 Cat X (day & night) requirements for Red, Blue, Amber see E2 in chart!
FLASH PATTERN
RED WIRE
LED Primary Color
UP 1&3, DN 5&7
Cycle Flash Color
0
1&3&5&7 only
Single 75FPM Ph1
2
Color 1&3&5&7 only
Single 75FPM Ph2
3
Color 1&3&5&7 only
Single 75FPM Alt
4
1&3&5&7 with 2&4&6&8
Single 75FPM Up-Dn
5
1&3 Alt 5&7 only
1
Single 75FPM Up-Dn
6
1&3 Alt 6&8 only
Single 75FPM Rt-Lt 1&5
7
Alt 3&7
Single 75FPM Diagonal
8
1&7 Alt 3&5
Single 75FPM CCW
9
1&3&5&7 only
Single 75FPM CW
10
1&3&5&7 only
FLASH PATTERN
WHITE WIRE
LED Secondary Color
UP 2&4, DN 6&8
Cycle Flash Color
no
2&4&6&8 only
Single 75FPM Ph1 Color
yes SC
2&4&6&8 only
Single 75FPM Ph2 Color
yes SC
2&4&6&8 only
Single 75FPM Alt
yes SC
2&4&6&8 with 1&3&5&7
Single 75FPM Up-Dn
yes S
2&4 Alt 6&8 only
Single 75FPM Up-Dn
yes S
5&7 Alt 2&4 only
Single 75FPM Rt-Lt 2&6
yes S
Alt 4&8
Single 75FPM Diagonal
yes S
2&8 Alt 4&6
Single 75FPM CCW
no
2&4&6&8 only
Single 75FPM CW
no
2&4&6&8 only
Steady Burn Color 1&3&5&7
no
0
only
Single 75FPM Rt-Lt 1&5 Alt
yes SC
2
4&8
Single 75FPM Rt-Lt 3&7 Alt
yes SC
3
2&6
Single 75FPM Diagonal 1&7
yes SC
4
Alt 4&6
Single 75FPM Diagonal 3&5
yes
S
5
Alt 2&8
1
Single 75FPM CCW
yes
S
6
1&3&5&7 Alt 2&4&6&8
Single 75FPM CCW
yes
S
7
2&4&6&8 Alt 1&3&5&7
Single 75FPM CW 1&3&5&7
yes
S
8
Alt 2&4&6&8
Single 75FPM CW 2&4&6&8
no
9
Alt 1&3&5&7
no
FLASH PATTERN
RED & WHITE WIRE (to-
gether)
LED Primary Color
UP 1&3, DN 5&7
LED Secondary Color
UP 2&4, DN 6&8
no
yes
S
yes
S
yes
S
yes
S
no
no
no
no
Page 3 of 8

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the XTP Series and is the answer not in the manual?

Questions and answers

This manual is also suitable for:

Xtp4dsmc

Table of Contents