Danfoss Ammonia IPS 8 User Manual page 22

Intelligent purging system
Hide thumbs Also See for Ammonia IPS 8:
Table of Contents

Advertisement

User Guide | Intelligent Purging System (IPS 8) Ammonia
Register Parameter Name
8123
Event3
8125
Event4
8127
Event5
8129
Event6
8131
Event7
8133
PP1
8135
PP2
8137
PP3
8139
PP4
8141
PP5
8143
PP6
8145
PP7
8147
PP8
8149
Val1
8150
Val2
8151
Val3
8152
Val4
8153
Val5
8154
Val6
8155
Val7
8156
Val8
8158
TempStatus
8159
BPLStatus
8160
BPHStatus
22 | BC344024774466en-000401
User
Description
Level
Purge cycle event -
counts the accumative
minutes that the
0
purge valve has been
open on a finished
cycle
Purge cycle event -
counts the accumative
minutes that the
0
purge valve has been
open on a finished
cycle
Purge cycle event -
counts the accumative
minutes that the
0
purge valve has been
open on a finished
cycle
Purge cycle event -
counts the accumative
minutes that the
0
purge valve has been
open on a finished
cycle
Purge cycle event -
counts the accumative
minutes that the
0
purge valve has been
open on a finished
cycle
The time percentage
0
for this purge point
The time percentage
0
for this purge point
The time percentage
0
for this purge point
The time percentage
0
for this purge point
The time percentage
0
for this purge point
The time percentage
0
for this purge point
The time percentage
0
for this purge point
The time percentage
0
for this purge point
This indicates if the
0
purge point is active
This indicates if the
0
purge point is active
This indicates if the
0
purge point is active
This indicates if the
0
purge point is active
This indicates if the
0
purge point is active
This indicates if the
0
purge point is active
This indicates if the
0
purge point is active
This indicates if the
0
purge point is active
The measured
temperature on the
0
discharge line of
compressor
The pressure on R452
0
The pressure on R717
0
Default
Min Value
Max Value
Value
-3276,8
3276,7
0
-3276,8
3276,7
0
-3276,8
3276,7
0
-3276,8
3276,7
0
-3276,8
3276,7
0
-32768
32767
0
-32768
32767
0
-32768
32767
0
-32768
32767
0
-32768
32767
0
-32768
32767
0
-32768
32767
0
-32768
32767
0
-32768
32767
0
-32768
32767
0
-32768
32767
0
-32768
32767
0
-32768
32767
0
-32768
32767
0
-32768
32767
0
-32768
32767
0
-32768
32767
0
-32768
32767
0
-2147483648
2147483647
0
Modbus
Unit/
Read/
Modbus
Function
Type
Write
Data Type
Code
Read
Minutes
3
Long
only
Read
Minutes
3
Long
only
Read
Minutes
3
Long
only
Read
Minutes
3
Long
only
Read
Minutes
3
Long
only
Read
%
3
Long
only
Read
%
3
Long
only
Read
%
3
Long
only
Read
%
3
Long
only
Read
%
3
Long
only
Read
%
3
Long
only
Read
%
3
Long
only
Read
%
3
Long
only
Read
N/A
3
Short
only
Read
N/A
3
Short
only
Read
N/A
3
Short
only
Read
N/A
3
Short
only
Read
N/A
3
Short
only
Read
N/A
3
Short
only
Read
N/A
3
Short
only
Read
N/A
3
Short
only
Read
°C
3
Short
only
Read
bar
3
Short
only
Read
bar
3
Short
only
© Danfoss | DCS (ms) | 2021.04
Persistent
Yes/No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Ammonia IPS 8 and is the answer not in the manual?

This manual is also suitable for:

084h5002

Table of Contents